Skip to main content
Schneider Electric A9FDB7610 — 1-Pole MCB (DIN Rail)

Schneider Electric A9FDB7610 Acti9 iDPN N Arc, 10A B-Curve A

MPNA9FDB7610
Obsolete

Schneider Electric Acti9 iDPN N Arc, arc fault detection circuit breaker (AFDD), 1P+N, 10 A, B-curve, 6 kA Icn, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9FDB7610 — Identification
ParameterValue
Product nameActi9 iDPN N Arc
Product / component typeArc fault detection circuit breaker
Product rangeActi9
Device short nameiDPN N Arc
Poles description1P + N
Number of protected poles1
A9FDB7610 — Electrical & Protection
ParameterValue
Rated current (In)10 A at 30 °C
Rated operational voltage (Ue)230 V AC 50 Hz conforming to IEC 62606 230 V AC 50 Hz conforming to EN/IEC 60898-1
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu / AIR)6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC
Network frequency50 Hz
Overvoltage categoryIII
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9FDB7610 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminal for 1 cable(s) 10 mm² flexible Tunnel type terminal for 2 cable(s) 2.5 mm² flexible Tunnel type terminal for 1 cable(s) 16 mm² rigid Tunnel type terminal for 2 cable(s) 2.5 mm² rigid
Mounting supportDIN rail
Mounting modeClip-on
Width36 mm
Height81 mm
Depth72 mm
Tightening torque (by circuit)2 N.m
A9FDB7610 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9FDB7610 — Approvals
ParameterValue
Conformity standardsIEC 60898-1 EN/IEC 62606
A9FDB7610 — Electrical
ParameterValue
[Ui] rated insulation voltage400 V AC
[Uimp] rated impulse withstand voltage4 kV conforming to IEC 60898-1

Product details

The Schneider Electric A9FDB7610 is an Acti9 iDPN N Arc arc fault detection circuit breaker (AFDD) — a 1P+N device rated 10 A at 30 °C with a B-curve trip characteristic and a 6000 A Icn breaking capacity at 230 V AC 50 Hz per EN/IEC 60898-1.

What sets this unit apart from a standard MCB is the integrated arc-fault detection. The thermal-magnetic trip handles overloads and short circuits (magnetic tripping between 3 and 5 times In for the B-curve), while the electronics monitor the waveform for the high-frequency signature of a series or parallel arc — the kind of fault a standard breaker won't catch. The limitation class 3 rating per IEC 60898-1 means it lets through very little energy during a short-circuit, which helps with downstream device coordination.

Mounts on DIN rail via the clip-on mechanism — 36 mm width (2 modules at 18 mm pitch). The toggle provides local signalling for ON, OFF, and fault trip positions.

Frequently asked questions

Where can I buy A9FDB7610 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity and target delivery window.

What is A9FDB7610's breaking capacity?

The breaking capacity is 6000 A Icn at 230 V AC 50 Hz, conforming to EN/IEC 60898-1.

What compliance standards does A9FDB7610 meet?

It conforms to IEC 60898-1 for circuit-breaker performance and EN/IEC 62606 for arc-fault detection devices. The tropicalisation rating is severity B per IEC 60068-2-30 for 28 days.

What is the difference between A9FDB7610 and a standard MCB?

A standard MCB provides only thermal-magnetic overcurrent protection. The A9FDB7610 adds series arc-fault detection per EN/IEC 62606, monitoring for the high-frequency signature of arcing faults that a standard breaker cannot detect.

MPN
A9FDB7610