Skip to main content
Schneider Electric A9K12206 — 2-Pole MCB (DIN Rail)

Schneider Electric A9K12206 Acti9 K60 MCB, 2P C-curve 6 A, 1

MPNA9K12206
Obsolete

Schneider Electric Acti9 K60, A9K12206, miniature circuit-breaker, 2P, C-curve, 6 A, 10 kA Icn at 400 V AC, DIN rail mount, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9K12206 — Identification
ParameterValue
Product nameActi9 K60
Series / familyActi9
Device short nameK60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9K12206 — Electrical
ParameterValue
Rated current [In]6 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC
Network frequency50/60 Hz
A9K12206 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu)10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]7500 A 75 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1
Overvoltage categoryII
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9K12206 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth70 mm
Mounting supportDIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals (downstream) 0.5...35 mm² rigid
Terminal tightening torque3.5 N.m top or bottom
Comb busbar / distribution block compatibilityDownside: biconnect
Local signalling / indicationWithout
Contact position indicatorNo
A9K12206 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-25...85 °C
Relative humidity95 % at 55 °C
A9K12206 — Approvals
ParameterValue
Standards / complianceEN/IEC 60898-1

Product details

Specification summary for procurement

The Schneider Electric A9K12206 is a 2-pole miniature circuit-breaker from the Acti9 K60 series, rated 6 A with a C-curve tripping characteristic (5...10 x In magnetic trip limit). Breaking capacity is 10 kA Icn at 400 V AC 50/60 Hz, fully compliant with EN/IEC 60898-1. The thermal-magnetic trip unit provides overcurrent and short-circuit protection for distribution circuits.

Fixed mounting on DIN rail (per). Tunnel-type terminals accept 0.5...35 mm² rigid conductors; strip length 14 mm, tightening torque 3.5 N·m. IP20 finger-safe protection. Rated insulation voltage 440 V AC, overvoltage category II.

Environmental and durability

Electrical and mechanical durability each rated at 20 000 cycles. Operating altitude 0...2000 m.

Frequently asked questions

Where can I buy A9K12206 and how do I get a price?

The A9K12206 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key specifications of A9K12206?

The A9K12206 is a 2-pole C-curve miniature circuit-breaker rated 6 A with 10 kA breaking capacity at 400 V AC, compliant with EN/IEC 60898-1.

What compliance documentation does this brand provide for A9K12206?

The part is certified to EN/IEC 60898-1 and carries tropicalisation class 2 per IEC 60068-1. The manufacturer provides standard compliance documentation for these standards.

MPN
A9K12206