Skip to main content
Schneider Electric A9K23425

Schneider Electric A9K23425 Acti9 iK60 MCB, 4P B-Curve 25 A

MPN A9K23425
Obsolete

Schneider Electric Acti9 iK60N, miniature circuit-breaker, 4P, B-curve, 25 A rated, 6 kA breaking capacity at 400 V AC, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9K23425 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to EN/IEC 60898-1

All specifications

A9K23425 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9K23425 is a 4-pole miniature circuit-breaker from the Acti9 iK60N series, rated 25 A at 30 °C with a B-curve trip characteristic (magnetic trip between 3 and 5 times In). Its 6 kA breaking capacity at 400 V AC (Icn per EN/IEC 60898-1) means it can safely interrupt a fault current up to 6000 A without welding contacts or cascading damage upstream — that's the standard domestic and light-commercial fault level for 400 V three-phase distribution boards across Europe and markets adopting IEC 60898-1. Clip-on mounting to a DIN rail (35 mm per EN 60715) and 72 mm width (8 x 9 mm pitches) mean it occupies exactly four module spaces in a consumer unit or sub-distribution board. The tunnel-type terminals accept up to 25 mm² rigid or 16 mm² flexible cable, with a 2 N·m tightening torque and 14 mm strip length — standard for a 25 A outgoing circuit. IP20 finger-safe terminals are fine for enclosed panels; no washdown rating here, so keep it inside the enclosure.

Coordination and selectivity notes

The thermal-magnetic trip unit gives a fixed thermal curve (ambient-compensated) and a magnetic threshold of 3–5 x In (75–125 A instantaneous). For motor-starting or transformer inrush, a C-curve or D-curve would be a better fit; the B-curve here is for general distribution.

MPN
A9K23425