Skip to main content
Schneider Electric A9K23463

Schneider Electric A9K23463 Acti9 iK60N MCB, 63 A, B Curve,

MPN A9K23463
Obsolete

Schneider Electric Acti9 iK60N miniature circuit-breaker, A9K23463, 63 A, B curve, 4P, 6 kA Icn at 400 V AC, thermal-magnetic trip, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9K23463 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to EN/IEC 60898-1

All specifications

A9K23463 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9K23463 is a 4-pole Acti9 iK60N miniature circuit-breaker rated 63 A at 30 °C with a B-curve trip characteristic (magnetic tripping between 3 and 5 times In). It clips onto a standard DIN rail and occupies 8 x 9 mm pitches (72 mm wide, 85 mm tall, 78.5 mm deep), so it fits a 4P slot in any Acti9 distribution board without crowding adjacent ways. Breaking capacity is 6 kA Icn at 400 V AC 50/60 Hz per EN/IEC 60898-1, which covers the majority of commercial and light industrial final-distribution boards where the prospective short-circuit current stays under that threshold. The limitation class is 3, meaning it lets through less energy than a class-3 limit curve — useful for protecting downstream cabling and loads without oversizing the breaker.

Trip unit and isolation

Thermal-magnetic trip technology handles overloads (thermal bimetal) and short-circuits (solenoid) in one compact package.

Durability and environment

Rated for 10,000 electrical cycles and 20,000 mechanical cycles — figures typical for a distribution MCB that sees occasional switching rather than daily load-break duty. The IP20 finger-safe terminals accept up to 35 mm² rigid wire with a 14 mm strip length; tightening torque is 3.5 N.m.

MPN
A9K23463