Schneider Electric A9K23650

Schneider Electric A9K23650 Acti9 iK60N MCB, 50 A, Curve B,

MPN A9K23650
Obsolete

Schneider Electric Acti9 iK60N, miniature circuit breaker, A9K23650, 50 A, curve B, 1P+N, 6 kA, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9K23650 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to EN/IEC 60898-1

All specifications

A9K23650 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9K23650 is a 50 A, curve B, 1P+N miniature circuit breaker from the Acti9 iK60N series, rated for 6 kA breaking capacity at 230 V AC per EN/IEC 60898-1.

In a panel with multiple breakers ganged together, derate per the manufacturer's table — typically 10–15 % if the ambient exceeds 40 °C or if the breaker is sandwiched between loaded units. For installations where the prospective short-circuit current (PSCC) at the breaker's location exceeds 6 kA, you need a higher-rated device upstream or a current-limiting fuse. The limitation class 3 rating means this breaker limits let-through energy to a level that protects downstream equipment during a fault. The 1P+N configuration switches the phase and switches the neutral, but the neutral pole is not protected — it opens and closes with the phase but does not have an overcurrent trip element. This is common in single-phase final distribution where the neutral is solidly bonded at the panel. The neutral position is left, which matters when aligning busbar connections in a multi-pole assembly.

The 36 mm width (4 modules) fits standard distribution board cutouts. Terminals accept 1 to 35 mm² rigid wire; strip 14 mm and torque to 3.5 N·m. The toggle actuator provides local ON/OFF indication. A padlocking device can be fitted to lock the breaker in the OFF position for lockout/tagout procedures.