Schneider Electric A9K24203 — 2-Pole MCB (DIN Rail)

Schneider Electric A9K24203 Acti9 iK60N MCB, 2P C-curve 3 A

MPNA9K24203
Active

Schneider Electric Acti9 iK60N miniature circuit breaker, A9K24203, 2-pole, C-curve, 3 A rated current, 6 kA breaking capacity at 400 V AC, thermal-magnetic trip, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9K24203 — Identification
ParameterValue
Product nameActi9 iK60
Series / familyActi9
Device short nameiK60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9K24203 — Electrical
ParameterValue
Rated current [In]3 A at 30 °C
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC
Network frequency50/60 Hz
A9K24203 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu)6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]6000 A 100 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1
Overvoltage categoryII
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9K24203 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth78.5 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom) 1...25 mm² rigid Tunnel type terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorNo
A9K24203 — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...85 °C
A9K24203 — Approvals
ParameterValue
Standards / complianceEN/IEC 60898-1

Product details

The Schneider Electric A9K24203 is a 2-pole miniature circuit breaker from the Acti9 iK60N series, rated 3 A with a C-curve trip characteristic and a 6 kA breaking capacity at 400 V AC. It's a thermal-magnetic device built to EN/IEC 60898-1 for distribution in residential or light commercial panels. The 36 mm width (4 x 9 mm pitches) clips onto standard DIN rail, so it slots into any existing Acti9 or Multi9 board without extra adapters.

The C-curve (5–10 x In magnetic trip) means it holds through mild inrush from LED drivers or small transformers but trips fast on a hard short.

Clip-on DIN rail mount, 36 mm wide — occupies two pole positions in a standard distribution board. Tunnel terminals accept 1–25 mm² rigid or 1–16 mm² flexible; strip 14 mm and torque to 2 N·m.

Frequently asked questions

Where can I buy A9K24203 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is A9K24203's listed depth (78.5 mm) on this component line?

The depth is 78.5 mm, which is standard for the Acti9 iK60N 2-pole form factor and fits most DIN-rail enclosures without depth clearance issues.

What compliance documentation does this brand provide for A9K24203?

The breaker is certified to EN/IEC 60898-1, carries an IP20 rating per IEC 60529, and is rated for isolation per the same standard. Schneider Electric typically provides CE declaration and RoHS/REACH compliance data on request for this series.

MPN