Skip to main content
Schneider Electric A9K24604 — 1-Pole MCB (DIN Rail)

Schneider Electric A9K24604 Acti9 iK60N MCB, 4 A C-Curve 1P+

MPNA9K24604
Obsolete

Schneider Electric Acti9 iK60N, A9K24604, miniature circuit-breaker, 4 A, C-curve, 1P+N, 6 kA Icn, EN/IEC 60898-1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9K24604 — Identification
ParameterValue
Product nameActi9 iK60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short nameiK60N
Poles description1P + N
Number of protected poles1
Device applicationDistribution
A9K24604 — Electrical & Protection
ParameterValue
Rated current (In)4 A at 30 °C
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryII
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9K24604 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminal (top or bottom) 1...25 mm² rigid Tunnel type terminal (top or bottom) 1...16 mm² flexible
Mounting supportDIN rail
Mounting modeClip-on
Width36 mm
Height85 mm
Depth78.5 mm
Tightening torque (by circuit)2 N.m top or bottom
A9K24604 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
A9K24604 — Approvals
ParameterValue
Conformity standardsEN/IEC 60898-1
A9K24604 — Electrical
ParameterValue
[Ui] rated insulation voltage440 V AC 50/60 Hz conforming to EN/IEC 60898-1
[Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60898-1

Product details

The A9K24604 is a Schneider Electric Acti9 iK60N miniature circuit-breaker rated 4 A at 30 °C with a C-curve (magnetic trip 5...10 x In), meaning it's sized for general-purpose branch circuits where moderate inrush — from small motors, transformers, or lighting ballasts — is expected. The 1P+N configuration (one protected pole plus switched neutral) suits single-phase final subcircuits where the neutral is switched with the phase, common in UK/EU split-load boards. The thermal-magnetic trip unit provides overload protection via the bimetal and short-circuit protection via the solenoid, with the C-curve's 5-10x In window balancing nuisance-tripping against fault clearance. Clip-on mounting to DIN rail (35 mm per EN 60715) and a width of 36 mm (4 x 9 mm pitches) means it occupies one standard module slot in a distribution board — critical for panel fill-factor planning. The IP20 finger-safe terminals (tunnel type, accepting 1...25 mm² rigid or 1...16 mm² flexible) are rated for enclosure-only use; no washdown or outdoor exposure. The white colour and ON/OFF toggle indication are standard for Acti9 residential ranges.

Limitation class 3 per that standard means it limits let-through energy effectively for downstream equipment protection. The suitability-for-isolation marking (yes, conforming to EN/IEC 60898-1) means it can be used as a disconnecting means for the circuit. No earth-leakage protection is integrated — that's handled by a separate RCD upstream.

Frequently asked questions

Where can I buy A9K24604 and what is the lead time?

The A9K24604 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead-time commitment.

What is the closest alternative to A9K24604 in the Acti9 range?

Within the Acti9 iK60N family, the closest sibling is the A9K24204 (same 1P+N, C-curve, 6 kA, but rated 2 A instead of 4 A). The form factor, terminal capacity, and breaking capacity are identical — the only delta is the thermal-magnetic trip rating. If you need a higher current, the A9K24606 (6 A) or A9K24610 (10 A) share the same physical footprint and curve.

What is A9K24604's depth?

The A9K24604 has a depth of 78.5 mm, a height of 85 mm, and a width of 36 mm (4 x 9 mm pitches).

What compliance documentation does Schneider provide for A9K24604?

The A9K24604 is designed and tested to EN/IEC 60898-1, the standard for AC miniature circuit-breakers. It carries limitation class 3, pollution degree 2, and overvoltage category II per that standard. The suitability-for-isolation marking confirms it meets the disconnection requirements of EN/IEC 60898-1. Standard Schneider documentation includes the declaration of conformity and test certificates available through their product documentation portal.

MPN