Skip to main content
Schneider Electric A9K24606 — 1-Pole MCB (DIN Rail)

Schneider Electric A9K24606 Acti9 iK60 MCB, 1P+N, 6 A, C-Cur

MPNA9K24606
Obsolete

Schneider Electric Acti9 iK60 miniature circuit breaker, A9K24606, 1P+N, 6 A rated current, C-curve, 6 kA breaking capacity at 230 V AC, thermal-magnetic trip, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9K24606 — Identification
ParameterValue
Product nameActi9 iK60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short nameiK60N
Poles description1P + N
Number of protected poles1
Device applicationDistribution
A9K24606 — Electrical & Protection
ParameterValue
Rated current (In)6 A at 30 °C
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryII
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9K24606 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminal (top or bottom) 1...25 mm² rigid Tunnel type terminal (top or bottom) 1...16 mm² flexible
Mounting supportDIN rail
Mounting modeClip-on
Width36 mm
Height85 mm
Depth78.5 mm
Tightening torque (by circuit)2 N.m top or bottom
A9K24606 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
A9K24606 — Approvals
ParameterValue
Conformity standardsEN/IEC 60898-1
A9K24606 — Electrical
ParameterValue
[Ui] rated insulation voltage440 V AC 50/60 Hz conforming to EN/IEC 60898-1
[Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60898-1

Product details

It is a 1-pole + neutral (1P+N) unit rated at 6 A at 30 °C, with a C-curve trip characteristic (magnetic tripping between 5 and 10 times the rated current). The thermal-magnetic trip unit provides overload protection (thermal bimetal) and short-circuit protection (magnetic coil) in a single device.

Deployment context — panel integration

The A9K24606 clips onto a standard 35 mm DIN rail (EN 60715) and occupies 4 x 9 mm pitches (36 mm width), leaving room for adjacent modules in a multi-row enclosure. The tunnel-type terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible cable; the recommended tightening torque is 2 N.m. Wire stripping length is 14 mm. The white housing carries an ON/OFF toggle indicator and a padlocking provision for lockout/tagout during maintenance.

Frequently asked questions

What is the A9K24606 used for?

It is a miniature circuit breaker for AC distribution boards, protecting downstream wiring and loads against overloads and short circuits. The 1P+N configuration switches the live conductor and provides a switched neutral, suitable for single-phase final circuits up to 6 A.

Where can I buy the A9K24606 and get current pricing?

The A9K24606 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance standards does the A9K24606 meet?

It is certified to EN/IEC 60898-1, with a limitation class of 3, pollution degree 2, and overvoltage category II. It is suitable for isolation per the same standard.

MPN