Schneider Electric A9K24732

A9K24732 Acti9 iK60N Miniature Circuit-Breaker, 32 A, C Curv

MPN A9K24732
Active

Schneider Electric Acti9 iK60N miniature circuit-breaker, A9K24732, 3P+N, 32 A rated, C curve, 6000 A breaking capacity at 400 V AC, thermal-magnetic trip, DIN rail clip-on, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9K24732 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to EN/IEC 60898-1

All specifications

A9K24732 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The A9K24732 is a Schneider Electric Acti9 iK60N miniature circuit-breaker — a thermal-magnetic MCB rated 32 A at 30 °C, with a C curve (magnetic trip between 5 and 10 times In) and a 6000 A breaking capacity at 400 V AC, 50/60 Hz, conforming to EN/IEC 60898-1. This is a 3P+N unit — three protected poles plus a switched neutral pole on the left. The neutral pole is not thermally protected; it switches with the phase poles, so it's suited for distribution schemes where the neutral is solidly bonded upstream and only needs disconnection for isolation. The part carries isolation suitability per EN/IEC 60898-1, meaning it can be used as a disconnecting means for the downstream circuit when padlocked off.

The 9 mm pitch count of 8 means the breaker occupies 8 modules (72 mm width) on the rail — plan your enclosure fill accordingly. Height is 85 mm, depth 78.5 mm, so it fits most distribution boards without crowding the gland plate. Tunnel-type terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible cable; strip 14 mm and tighten to 2 N.m. IP20 finger-safe front, but the terminals are live when wired — standard for distribution MCBs.

MPN
A9K24732