Skip to main content
Schneider Electric A9KF21132BQ

Schneider Electric A9KF21132BQ Acti9 K60 MCB, 32 A, Curve B,

MPN A9KF21132BQ
Active

Schneider Electric Acti9 K60 miniature circuit-breaker, A9KF21132BQ, 1P, 32 A, curve B, 10 kA Icn at 240 V AC, EN/IEC 60898-1, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9KF21132BQ key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Pollution degree2

All specifications

A9KF21132BQ additional specifications
ParameterValue
ColorWhite
Depth70 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-5...55 °C

Product details

The Schneider Electric A9KF21132BQ is a 1-pole miniature circuit-breaker from the Acti9 K60 series, rated 32 A with a B-curve trip characteristic. It protects branch circuits in residential and light commercial distribution boards, tripping magnetically between 3 and 5 times rated current for fast response to short circuits while allowing moderate inrush from resistive loads.

Breaking capacity and standard compliance

Rated breaking capacity is 10 kA Icn at 240 V AC, 50/60 Hz, certified to EN/IEC 60898-1. That 10 kA figure is the maximum prospective fault current the breaker can safely interrupt under standard conditions — sufficient for most final sub-circuits in a TN or TT system where the fault level at the board stays under that threshold. Limitation class 3 per EN/IEC 60898-1 means it limits let-through energy effectively, reducing stress on downstream equipment during a fault.

Mounting and integration

Snaps onto a standard 35 mm DIN rail, occupying 2 x 9 mm pitches (18 mm total width). Tunnel terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible copper, with a tightening torque of 2 N.m. Wire strip length is 14 mm for both top and bottom connections. The IP20 finger-safe enclosure suits enclosed distribution boards; not rated for washdown or outdoor exposure.

MPN