Skip to main content
Schneider Electric A9KF71101BQ

Schneider Electric A9KF71101BQ Acti9 K60 MCB, 1A C-Curve, 10

MPN A9KF71101BQ
Active

Schneider Electric Acti9 K60 miniature circuit breaker, A9KF71101BQ, 1A rated current, C-curve, 10kA breaking capacity, 1P, 18mm wide, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9KF71101BQ key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Pollution degree2

All specifications

A9KF71101BQ additional specifications
ParameterValue
ColorWhite
Depth70 mm
Width18 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-5...55 °C

Product details

The Schneider Electric A9KF71101BQ is a 1A miniature circuit breaker from the Acti9 K60 series, built for distribution boards and sub-panels where a single-pole, C-curve thermal-magnetic trip protects a 1A branch circuit. The 18mm width (2 x 9mm pitches) fits a standard DIN-rail enclosure, and the IP20 finger-safe terminals accept up to 25mm² rigid or 16mm² flexible cable.

The C-curve (magnetic trip at 5–10 x In) means this breaker holds through moderate inrush — typical for small transformers, lighting ballasts, or control-circuit power supplies — and trips fast on a hard short. The thermal-magnetic trip unit combines a bimetal strip for overload protection and a solenoid for short-circuit; no electronic adjustment, so it's a fit-and-forget part for fixed loads.

Panel integration

Snaps onto a standard 35mm DIN rail — no tools needed for mounting. The 18mm width occupies two 9mm module pitches, so plan for that footprint in your enclosure layout. Tunnel-type terminals accept 1–25mm² rigid or 1–16mm² flexible cable; strip 14mm and torque to 2 N·m for both line and load connections. The toggle control gives a clear visual on/off state. Operating altitude is 0–2000m; above that, derate the dielectric withstand. Pollution degree 2 covers normal indoor environments with only non-conductive contamination.

MPN
A9KF71101BQ