Schneider Electric A9KF71116BQ — 1-Pole MCB (DIN Rail)

Schneider Electric A9KF71116BQ Acti9 K60 MCB, 16 A, C Curve,

MPNA9KF71116BQ
Active

Schneider Electric Acti9 K60 miniature circuit-breaker, A9KF71116BQ, 1P, 16 A, C curve, 10 kA Icn at 240 V AC, thermal-magnetic, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9KF71116BQ — Identification
ParameterValue
Product nameActi9 K60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short nameK60H
Poles description1P
Number of protected poles1
Device applicationDistribution
A9KF71116BQ — Electrical & Protection
ParameterValue
Rated current (In)16 A
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryII
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9KF71116BQ — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible
Mounting supportDIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth70 mm
Tightening torque (by circuit)2 N.m top or bottom
A9KF71116BQ — Environmental
ParameterValue
Operating ambient temperature-5...55 °C
Storage ambient temperature-25...85 °C
IP degree of protectionIP20 conforming to IEC 60529
A9KF71116BQ — Approvals
ParameterValue
Conformity standardsEN/IEC 60898-1
A9KF71116BQ — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV

Product details

The Schneider Electric A9KF71116BQ is a 1-pole miniature circuit-breaker from the Acti9 K60 series, rated 16 A with a C curve and a breaking capacity of 10 kA Icn at 240 V AC, 50/60 Hz, per EN/IEC 60898-1.

Mounts on a standard DIN rail (35 mm) — the 18 mm width (2 x 9 mm pitches) fits a single-module slot in any Acti9 or third-party enclosure. The tunnel terminals accept 1–25 mm² rigid or 1–16 mm² flexible conductors, with a wire-stripping length of 14 mm and a tightening torque of 2 N·m. That's a solid grip for 6 mm² or 10 mm² feed conductors common in final distribution circuits.

Durability and environment

Rated for 20,000 electrical and 20,000 mechanical cycles — enough for frequent switching in lighting or small motor circuits. The IP20 finger-safe terminals suit enclosed panel installation; tropicalisation class 2 per IEC 60068-1 handles 95 % relative humidity at 55 °C, so it holds up in hot, humid plant environments without internal corrosion. Pollution degree 2 (non-conductive dust, occasional condensation) is the standard for clean commercial and light industrial panels.

Certified to EN/IEC 60898-1 for overcurrent protection in household and similar installations. Suitable for isolation per that standard — confirmed by the manufacturer.

Frequently asked questions

What is the breaking capacity of A9KF71116BQ?

The A9KF71116BQ has a breaking capacity of 10,000 A Icn at 240 V AC, 50/60 Hz, conforming to EN/IEC 60898-1.

What is the closest alternative to A9KF71116BQ?

Within the Acti9 K60 range, the closest alternative is a different current rating or pole configuration — the same C curve, 10 kA breaking capacity, and DIN-rail footprint. No pin-compatible alternate from another brand is listed in the manufacturer's documentation.

Where can I buy A9KF71116BQ and how is it quoted?

The A9KF71116BQ is sourced to order through independent distribution. Availability and current pricing are confirmed at the time of an RFQ — no stock count or price is published here.

MPN