Skip to main content
Schneider Electric A9KF71125BQ — 1-Pole MCB (DIN Rail)

Schneider Electric A9KF71125BQ Acti9 K60 MCB, 25 A, 1P, C-Cu

MPNA9KF71125BQ
Active

Schneider Electric Acti9 K60 miniature circuit-breaker, A9KF71125BQ, 1P, 25 A, C-curve, 10 kA Icn at 240 V AC, EN/IEC 60898-1, DIN rail mount, thermal-magnetic trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9KF71125BQ — Identification
ParameterValue
Product nameActi9 K60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short nameK60H
Poles description1P
Number of protected poles1
Device applicationDistribution
A9KF71125BQ — Electrical & Protection
ParameterValue
Rated current (In)25 A
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryII
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9KF71125BQ — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible
Mounting supportDIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth70 mm
Tightening torque (by circuit)2 N.m top or bottom
A9KF71125BQ — Environmental
ParameterValue
Operating ambient temperature-5...55 °C
Storage ambient temperature-25...85 °C
IP degree of protectionIP20 conforming to IEC 60529
A9KF71125BQ — Approvals
ParameterValue
Conformity standardsEN/IEC 60898-1
A9KF71125BQ — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV

Product details

The Schneider Electric A9KF71125BQ is a 1-pole miniature circuit-breaker from the Acti9 K60 series, rated 25 A with a C-curve trip characteristic.

Where it fits and how to mount it

Tighten to 2 N·m, strip 14 mm. IP20 finger-safe front, pollution degree 2, overvoltage category II. Rated for altitudes up to 2000 m and 95 % RH at 55 °C (tropicalisation class 2 per IEC 60068-1).

Frequently asked questions

What is the breaking capacity of A9KF71125BQ?

10,000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1, which means it safely interrupts fault currents up to that level without welding contacts or failing to clear.

What compliance standards does A9KF71125BQ meet?

Designed and certified to EN/IEC 60898-1 for miniature circuit-breakers, with suitability for isolation confirmed per that standard. Tropicalisation class 2 per IEC 60068-1. IP20 per IEC 60529.

Where can I buy A9KF71125BQ?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price shown here.

MPN
A9KF71125BQ