Skip to main content
Schneider Electric A9KF71216BQ — 2-Pole MCB (DIN Rail)

Schneider Electric A9KF71216BQ Acti9 K60 MCB, 16 A, 2P, C-Cu

MPNA9KF71216BQ
Active

Schneider Electric Acti9 K60, miniature circuit breaker, 2P, 16 A, C-curve, 10 kA Icn at 415 V AC, EN/IEC 60898-1, DIN rail mount, white.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9KF71216BQ — Identification
ParameterValue
Product nameActi9 K60
Series / familyActi9
Device short nameK60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9KF71216BQ — Electrical
ParameterValue
Rated current [In]16 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC
Network frequency50/60 Hz
A9KF71216BQ — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu)10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1
Overvoltage categoryII
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9KF71216BQ — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth70 mm
Mounting supportDIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Comb busbar / distribution block compatibilityDownstream: biconnect
Local signalling / indicationWithout
Contact position indicatorNo
A9KF71216BQ — Environmental
ParameterValue
Operating temperature range-5...55 °C
Storage temperature range-25...85 °C
Relative humidity95 % at 55 °C
A9KF71216BQ — Approvals
ParameterValue
Standards / complianceEN/IEC 60898-1

Product details

The Schneider Electric A9KF71216BQ is a 2-pole miniature circuit breaker from the Acti9 K60 series, rated 16 A with a C-curve trip characteristic.

The 70 mm depth leaves clearance in shallow enclosures — fits flush in most Schneider Prisma or Resi9 boards. Tunnel terminals accept 1–25 mm² rigid or 1–16 mm² flexible, with a 2 N·m tightening torque. Strip length 14 mm top and bottom. IP20 finger-safe terminals; suitable for dry indoor panels only.

Frequently asked questions

What is the breaking capacity of A9KF71216BQ?

10 kA Icn at 415 V AC, 50/60 Hz, conforming to EN/IEC 60898-1.

What is the rated current and curve of A9KF71216BQ?

16 A, C-curve (magnetic trip 5–10 × In), 2-pole, thermal-magnetic trip unit.

How do I get current pricing and availability for A9KF71216BQ?

Submit an RFQ through this page. Availability and current pricing are confirmed at quote time through independent distribution channels.

MPN
A9KF71216BQ