Skip to main content
Schneider Electric A9KF71220BQ

Schneider Electric A9KF71220BQ Acti9 K60 MCB, 20 A C-Curve 2

MPN A9KF71220BQ
Active

Schneider Electric Acti9 K60 miniature circuit breaker, A9KF71220BQ, 20 A rated current, C-curve trip characteristic, 2-pole, 10 kA breaking capacity at 415 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9KF71220BQ key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Pollution degree2

All specifications

A9KF71220BQ additional specifications
ParameterValue
ColorWhite
Depth70 mm
Width36 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-5...55 °C

Product details

The Schneider Electric A9KF71220BQ is a 20 A, C-curve, 2-pole miniature circuit breaker from the Acti9 K60 series, built for distribution boards and final-subcircuit protection on AC networks at 50/60 Hz.

Rated 20 A continuous, this breaker protects a circuit sized for that load — think a 20 A lighting distribution board, a small HVAC fan coil, or a bank of office sockets. The 10 kA Icn breaking capacity at 415 V AC (EN/IEC 60898-1) tells you it can safely interrupt a fault current up to 10,000 A at that voltage, which covers most commercial and light-industrial installations where the prospective short-circuit current at the board is under that threshold. If your site's fault level exceeds 10 kA, you need a higher-rated device upstream or a current-limiting MCB. The 2-pole construction (2P) switches both line and neutral on a single-phase supply, or one pole per phase on a two-phase circuit. Thermal-magnetic trip technology means it responds to both sustained overloads (thermal bimetal) and short-circuit faults (magnetic coil) — no electronics to fail, no auxiliary power needed.

IP20 finger-safe terminals are fine inside a closed panel; no washdown rating here, so keep it dry.

MPN
A9KF71220BQ