Schneider Electric A9KF71302BQ — Circuit Breaker Accessories

Schneider Electric A9KF71302BQ Acti9 K60 MCB, 3P C-Curve 2A,

MPNA9KF71302BQ
Active

Schneider Electric Acti9 K60 miniature circuit-breaker, A9KF71302BQ, 3P, C-curve, 2 A rated current, 10 kA breaking capacity at 415 V AC, EN/IEC 60898-1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9KF71302BQ — Identification
ParameterValue
Product / component typeMiniature circuit-breaker
Product nameActi9 K60
Product rangeActi9
Device applicationDistribution
A9KF71302BQ — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]2 A
Rated insulation voltage [Ui]500 V AC 50/60 Hz
Rated impulse withstand voltage [Uimp]4 kV
Network frequency50/60 Hz
Poles description3P
Magnetic tripping limit5...10 x In
A9KF71302BQ — Protection & Performance
ParameterValue
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60898-1
Mechanical durability20000 cycles
Electrical durability20000 cycles
Local signallingWithout
Contact position indicatorNo
A9KF71302BQ — Mechanical
ParameterValue
Connections / terminalsTunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible
Device short nameK60H
Control typeToggle
Mounting modeFixed
Mounting supportDIN rail
Usable 9 mm pitches6
Width54 mm
Height81 mm
Depth70 mm
ColourWhite
A9KF71302BQ — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree2
Operating ambient air temperature-5...55 °C
Storage ambient air temperature-25...85 °C
A9KF71302BQ — Approvals
ParameterValue
StandardsEN/IEC 60898-1
A9KF71302BQ — Specifications
ParameterValue
Curve codeC
Number of protected poles3

Product details

The Schneider Electric A9KF71302BQ is a 3-pole miniature circuit-breaker from the Acti9 K60 range, rated 2 A with a C-curve trip characteristic (magnetic trip between 5 and 10 times In). It breaks 10 kA at 415 V AC, 50/60 Hz, certified to EN/IEC 60898-1 for branch-circuit protection in distribution boards.

The 2 A rating protects a small-load branch — think control transformers, signal-conditioner supplies, or lighting circuits drawing under 2 A continuous. The C curve (5–10× In) means the magnetic trip holds through moderate inrush, so it suits mixed resistive and lightly inductive loads without nuisance tripping on startup. Thermal-magnetic trip technology uses a bimetal strip for overload protection (the thermal element) and a solenoid for short-circuit protection (the magnetic element). The 2 A thermal element responds to sustained overcurrents; the magnetic element clears fast on high faults. For a 2 A branch, that matters most when the fault current is high relative to the wire rating.

Snap-on DIN-rail mount, 6 module pitches (9 mm each = 54 mm wide), fixed in the distribution board. Tunnel terminals accept 1–25 mm² rigid or 1–16 mm² flexible copper; strip 14 mm and torque to 2 N·m. Rated for altitudes up to 2000 m, pollution degree 2 (normal factory-floor environment), and tropicalised to IEC 60068-1 class 2 for 95 % RH at 55 °C. That covers most indoor industrial and commercial enclosures without derating.

MPN
A9KF71302BQ