Skip to main content
Schneider Electric A9KF71302BQ

Schneider Electric A9KF71302BQ Acti9 K60 MCB, 3P C-Curve 2A,

MPN A9KF71302BQ
Active

Schneider Electric Acti9 K60 miniature circuit-breaker, A9KF71302BQ, 3P, C-curve, 2 A rated current, 10 kA breaking capacity at 415 V AC, EN/IEC 60898-1.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9KF71302BQ key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Pollution degree2

All specifications

A9KF71302BQ additional specifications
ParameterValue
ColorWhite
Depth70 mm
Width54 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-5...55 °C

Product details

The Schneider Electric A9KF71302BQ is a 3-pole miniature circuit-breaker from the Acti9 K60 range, rated 2 A with a C-curve trip characteristic (magnetic trip between 5 and 10 times In). It breaks 10 kA at 415 V AC, 50/60 Hz, certified to EN/IEC 60898-1 for branch-circuit protection in distribution boards.

The 2 A rating protects a small-load branch — think control transformers, signal-conditioner supplies, or lighting circuits drawing under 2 A continuous. The C curve (5–10× In) means the magnetic trip holds through moderate inrush, so it suits mixed resistive and lightly inductive loads without nuisance tripping on startup. Thermal-magnetic trip technology uses a bimetal strip for overload protection (the thermal element) and a solenoid for short-circuit protection (the magnetic element). The 2 A thermal element responds to sustained overcurrents; the magnetic element clears fast on high faults. For a 2 A branch, that matters most when the fault current is high relative to the wire rating.

Snap-on DIN-rail mount, 6 module pitches (9 mm each = 54 mm wide), fixed in the distribution board. Tunnel terminals accept 1–25 mm² rigid or 1–16 mm² flexible copper; strip 14 mm and torque to 2 N·m. Rated for altitudes up to 2000 m, pollution degree 2 (normal factory-floor environment), and tropicalised to IEC 60068-1 class 2 for 95 % RH at 55 °C. That covers most indoor industrial and commercial enclosures without derating.

MPN
A9KF71302BQ