Skip to main content
Schneider Electric A9KF71310BQ

Schneider A9KF71310BQ Acti9 K60 3P C-10A MCB, 10 kA

MPN A9KF71310BQ
Active

Schneider Electric Acti9 K60, A9KF71310BQ, 3-pole miniature circuit-breaker, C-curve, 10 A rated current, 10 kA Icn breaking capacity at 415 V AC, DIN rail mount, thermal-magnetic trip.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9KF71310BQ key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Pollution degree2

All specifications

A9KF71310BQ additional specifications
ParameterValue
ColorWhite
Depth70 mm
Width54 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-5...55 °C

Product details

The Schneider Electric A9KF71310BQ is a 3-pole miniature circuit-breaker from the Acti9 K60 series, rated 10 A with a C-curve magnetic trip characteristic (5–10 × In). It breaks 10 kA Icn at 415 V AC, 50/60 Hz, certified to EN/IEC 60898-1. Thermal-magnetic trip unit, no earth-leakage protection. This is the 6-module width (54 mm) version, set of 4 per package.

Limitation class 3 (energy let-through) limits downstream stress during a fault. Snaps onto standard DIN rail. The 54 mm width (6 × 9 mm pitches) fits a 3-pole breaker in a standard distribution board.

Within the Acti9 K60 family, the A9KF71310BQ is the 3-pole, 10 A, C-curve variant. The same physical footprint and breaking capacity is shared across the K60H range; the only variable is the rated current and curve choice. If the BOM requires a different amp rating or a B/D curve, the K60 line covers those — but the 3-pole 10 A C-curve is a common pick for general-purpose motor and lighting sub-circuits.

Pollution degree 2 (non-conductive, occasional condensation). Operating altitude to 2000 m, overvoltage category II. Electrical and mechanical durability both rated at 20,000 cycles.

MPN