Schneider Electric A9KF71320BQ — Circuit Breaker Accessories

Schneider Electric A9KF71320BQ Acti9 K60 MCB, 20 A, 3P, C Cu

MPNA9KF71320BQ
Active

Schneider Electric Acti9 K60 miniature circuit-breaker, A9KF71320BQ, 3-pole, 20 A rated, C curve, 10 kA breaking capacity at 415 V AC, DIN rail mount, EN/IEC 60898-1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9KF71320BQ — Identification
ParameterValue
Product / component typeMiniature circuit-breaker
Product nameActi9 K60
Product rangeActi9
Device applicationDistribution
A9KF71320BQ — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]20 A
Rated insulation voltage [Ui]500 V AC 50/60 Hz
Rated impulse withstand voltage [Uimp]4 kV
Network frequency50/60 Hz
Poles description3P
Magnetic tripping limit5...10 x In
A9KF71320BQ — Protection & Performance
ParameterValue
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60898-1
Mechanical durability20000 cycles
Electrical durability20000 cycles
Local signallingWithout
Contact position indicatorNo
A9KF71320BQ — Mechanical
ParameterValue
Connections / terminalsTunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible
Device short nameK60H
Control typeToggle
Mounting modeFixed
Mounting supportDIN rail
Usable 9 mm pitches6
Width54 mm
Height81 mm
Depth70 mm
ColourWhite
A9KF71320BQ — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree2
Operating ambient air temperature-5...55 °C
Storage ambient air temperature-25...85 °C
A9KF71320BQ — Approvals
ParameterValue
StandardsEN/IEC 60898-1
A9KF71320BQ — Specifications
ParameterValue
Curve codeC
Number of protected poles3

Product details

Acti9 K60 MCB, 20 A, 3P, C Curve — Panel Fit and Protection

The Schneider Electric A9KF71320BQ is an Acti9 K60 miniature circuit-breaker rated 20 A with a C trip curve (magnetic tripping between 5 and 10 times In).

The 20 A rating governs continuous load capacity — this MCB carries 20 A without tripping under normal conditions. The C curve (5–10 x In) means magnetic trip occurs between 100 A and 200 A, suited for circuits with moderate inrush like lighting banks or small motor loads where a B curve would nuisance-trip.

Integration Notes — DIN Rail and Panel Wiring

Terminals accept 1–25 mm² rigid or 1–16 mm² flexible copper; strip 14 mm and torque to 2 N·m. The toggle control provides visual indication of trip status. IP20 finger-safe protection is standard for enclosed panels.

Frequently asked questions

How do I get pricing and availability for A9KF71320BQ?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; current pricing and stock levels are confirmed at quote time.

What is the closest alternative to A9KF71320BQ in the Acti9 range?

Within the Acti9 K60 family, the closest sibling is the same 3P C-curve MCB at a different current rating — for example, the 16 A variant (A9KF71316BQ) or 25 A variant (A9KF71325BQ). All share the same 54 mm width, DIN-rail mount, and 10 kA breaking capacity; only the In rating changes.

What compliance documentation does Schneider provide for A9KF71320BQ?

The MCB is certified to EN/IEC 60898-1 and carries tropicalisation class 2 per IEC 60068-1. Standard Schneider declarations of conformity (CE, UKCA) are available; RoHS and REACH compliance is typical for the Acti9 range but should be confirmed at order.

MPN