Skip to main content
Schneider Electric A9KF71401BQ — Circuit Breaker Accessories

Schneider Electric A9KF71401BQ Acti9 K60 MCB, C-curve 1A 4P

MPNA9KF71401BQ
Active

Schneider Electric Acti9 K60, miniature circuit breaker, 4P, 1 A, C-curve, 10 kA Icn at 415 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9KF71401BQ — Identification
ParameterValue
Product / component typeMiniature circuit-breaker
Product nameActi9 K60
Product rangeActi9
Device applicationDistribution
A9KF71401BQ — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]1 A
Rated insulation voltage [Ui]500 V AC 50/60 Hz
Rated impulse withstand voltage [Uimp]4 kV
Network frequency50/60 Hz
Poles description4P
Magnetic tripping limit5...10 x In
A9KF71401BQ — Protection & Performance
ParameterValue
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60898-1
Mechanical durability20000 cycles
Electrical durability20000 cycles
Local signallingWithout
Contact position indicatorNo
A9KF71401BQ — Mechanical
ParameterValue
Connections / terminalsTunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible
Device short nameK60H
Control typeToggle
Mounting modeFixed
Mounting supportDIN rail
Usable 9 mm pitches8
Width72 mm
Height81 mm
Depth70 mm
ColourWhite
A9KF71401BQ — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree2
Operating ambient air temperature-5...55 °C
Storage ambient air temperature-25...85 °C
A9KF71401BQ — Approvals
ParameterValue
StandardsEN/IEC 60898-1
A9KF71401BQ — Specifications
ParameterValue
Curve codeC
Number of protected poles4

Product details

What this 1 A C-curve MCB is for

The Schneider Electric A9KF71401BQ is an Acti9 K60 miniature circuit breaker — 4 poles, rated 1 A, C-curve, with a 10 kA Icn breaking capacity at 415 V AC per EN/IEC 60898-1. Rated 1 A continuous, so it guards a single small load — not a branch circuit.

Snaps onto standard DIN rail (mounting support: DIN rail). Occupies 8 x 9 mm pitches — 72 mm wide for the 4P body. Depth 70 mm, height 81 mm. Tunnel terminals accept 1–25 mm² rigid or 1–16 mm² flexible; wire strip length 14 mm, tighten to 2 N·m. That keeps the footprint tight in a distribution board or sub-panel where space is already allocated per pole. IP20 finger-safe front (IEC 60529), so it suits enclosed panels only — not washdown or outdoor without a secondary enclosure. Pollution degree 2, overvoltage category II, tropicalisation class 2 per IEC 60068-1 (handles 95 % RH at 55 °C). That covers most climate-controlled or sheltered industrial environments.

The Acti9 K60 series (short name K60H) is Schneider's standard MCB line for distribution boards.

If your load draws even 1.1 A steady, this breaker will eventually trip on the thermal element. The 20 000 electrical / 20 000 mechanical cycles match the expected life of a panel-mounted distribution breaker that sees infrequent operation.

Frequently asked questions

What compliance documentation does Schneider provide for A9KF71401BQ?

The MCB is certified to EN/IEC 60898-1, carries IP20 per IEC 60529, and meets tropicalisation class 2 per IEC 60068-1. Schneider typically provides CE declaration, RoHS, and REACH documentation for the Acti9 series upon request.

MPN
A9KF71401BQ