Specifications

A9KF71402BQ — Identification
ParameterValue
Product / component typeMiniature circuit-breaker
Product nameActi9 K60
Product rangeActi9
Device applicationDistribution
A9KF71402BQ — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]2 A
Rated insulation voltage [Ui]500 V AC 50/60 Hz
Rated impulse withstand voltage [Uimp]4 kV
Network frequency50/60 Hz
Poles description4P
Magnetic tripping limit5...10 x In
A9KF71402BQ — Protection & Performance
ParameterValue
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60898-1
Mechanical durability20000 cycles
Electrical durability20000 cycles
Local signallingWithout
Contact position indicatorNo
A9KF71402BQ — Mechanical
ParameterValue
Connections / terminalsTunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible
Device short nameK60H
Control typeToggle
Mounting modeFixed
Mounting supportDIN rail
Usable 9 mm pitches8
Width72 mm
Height81 mm
Depth70 mm
ColourWhite
A9KF71402BQ — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree2
Operating ambient air temperature-5...55 °C
Storage ambient air temperature-25...85 °C
A9KF71402BQ — Approvals
ParameterValue
StandardsEN/IEC 60898-1
A9KF71402BQ — Specifications
ParameterValue
Curve codeC
Number of protected poles4

Product details

The Schneider Electric A9KF71402BQ is a 4-pole miniature circuit breaker from the Acti9 K60 series, rated 2 A with a C-curve trip characteristic (magnetic trip between 5 and 10 times In). The thermal-magnetic trip unit handles overloads (thermal bimetal) and short circuits (magnetic coil) in one compact package.

Snaps onto a standard DIN rail (35 mm) — the 9 mm pitch count of 8 gives a 72 mm width, so a 4P breaker occupies four modular spaces. Fixed mounting, toggle control, IP20 finger-safe terminals. The tunnel-type terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible copper, with a 14 mm strip length and 2 Nm tightening torque. This is a panel-mount part for distribution boards; the set-of-3 packaging means you get three identical units per order code.

Rated for pollution degree 2 (normal factory/office environment), overvoltage category II, and tropicalisation class 2 per IEC 60068-1 (handles 95% RH at 55 °C).

Frequently asked questions

Where can I buy A9KF71402BQ and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of A9KF71402BQ?

10,000 A Icn at 415 V AC, 50/60 Hz, conforming to EN/IEC 60898-1 — the standard rating for a final-distribution MCB in a commercial panel.

What does the C-curve mean on this breaker?

The magnetic trip operates between 5 and 10 times the rated current (2 A), so the breaker holds moderate inrush from lighting or small motor loads but trips fast on a hard short.

MPN
A9KF71402BQ