Schneider Electric A9KF71410BQ — Circuit Breaker Accessories

A9KF71410BQ Acti9 K60 MCB, 4P C-curve 10 A, 10 kA

MPNA9KF71410BQ
Active

Schneider Electric Acti9 K60 miniature circuit-breaker, 4P, C-curve 10 A, breaking capacity 10 kA at 415 V AC, EN/IEC 60898-1, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9KF71410BQ — Identification
ParameterValue
Product / component typeMiniature circuit-breaker
Product nameActi9 K60
Product rangeActi9
Device applicationDistribution
A9KF71410BQ — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]10 A
Rated insulation voltage [Ui]500 V AC 50/60 Hz
Rated impulse withstand voltage [Uimp]4 kV
Network frequency50/60 Hz
Poles description4P
Magnetic tripping limit5...10 x In
A9KF71410BQ — Protection & Performance
ParameterValue
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60898-1
Mechanical durability20000 cycles
Electrical durability20000 cycles
Local signallingWithout
Contact position indicatorNo
A9KF71410BQ — Mechanical
ParameterValue
Connections / terminalsTunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible
Device short nameK60H
Control typeToggle
Mounting modeFixed
Mounting supportDIN rail
Usable 9 mm pitches8
Width72 mm
Height81 mm
Depth70 mm
ColourWhite
A9KF71410BQ — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree2
Operating ambient air temperature-5...55 °C
Storage ambient air temperature-25...85 °C
A9KF71410BQ — Approvals
ParameterValue
StandardsEN/IEC 60898-1
A9KF71410BQ — Specifications
ParameterValue
Curve codeC
Number of protected poles4

Product details

The Schneider Electric Acti9 K60 miniature circuit-breaker A9KF71410BQ is a 4-pole, C-curve 10 A MCB rated for 10 kA breaking capacity at 415 V AC per EN/IEC 60898-1. It is a current-production part.

C-curve means magnetic trip between 5 and 10 times rated current — 50 to 100 A for this 10 A breaker. Thermal-magnetic trip technology — the thermal bimetal handles overloads (slow, inverse-time), the solenoid handles short-circuits (instantaneous above the magnetic threshold). No electronics to fail, no auxiliary power needed. Simple, field-serviceable, and what every MRO guy wants on the van. Saves a separate isolator in many distribution boards.

Snap-on DIN rail mount, 72 mm wide (8 x 9 mm pitches). Occupies 4 pole spaces on the rail. Tunnel terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible — enough for most 10 A branch circuits. Tightening torque 2 N.m top and bottom. Wire strip length 14 mm. IP20 finger-safe terminals. Set of 3 — so you get three identical 4P breakers in one order. That's handy for a three-phase panel where you need the same rating on multiple feeders.

Frequently asked questions

What compliance documentation does this brand provide for A9KF71410BQ?

The breaker is certified to EN/IEC 60898-1. Tropicalisation class 2 per IEC 60068-1. Pollution degree 2. Overvoltage category II.

MPN