Skip to main content
Schneider Electric A9KF71420BQ — Circuit Breaker Accessories

Schneider Electric A9KF71420BQ Acti9 K60 MCB, 20A 4P C-Curve

MPNA9KF71420BQ
Active

Schneider Electric Acti9 K60, 4P miniature circuit breaker, 20 A rated current, C-curve, 10 kA Icn at 415 V AC, DIN-rail mount, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9KF71420BQ — Identification
ParameterValue
Product / component typeMiniature circuit-breaker
Product nameActi9 K60
Product rangeActi9
Device applicationDistribution
A9KF71420BQ — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]20 A
Rated insulation voltage [Ui]500 V AC 50/60 Hz
Rated impulse withstand voltage [Uimp]4 kV
Network frequency50/60 Hz
Poles description4P
Magnetic tripping limit5...10 x In
A9KF71420BQ — Protection & Performance
ParameterValue
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60898-1
Mechanical durability20000 cycles
Electrical durability20000 cycles
Local signallingWithout
Contact position indicatorNo
A9KF71420BQ — Mechanical
ParameterValue
Connections / terminalsTunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible
Device short nameK60H
Control typeToggle
Mounting modeFixed
Mounting supportDIN rail
Usable 9 mm pitches8
Width72 mm
Height81 mm
Depth70 mm
ColourWhite
A9KF71420BQ — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree2
Operating ambient air temperature-5...55 °C
Storage ambient air temperature-25...85 °C
A9KF71420BQ — Approvals
ParameterValue
StandardsEN/IEC 60898-1
A9KF71420BQ — Specifications
ParameterValue
Curve codeC
Number of protected poles4

Product details

The Schneider Electric A9KF71420BQ is an Acti9 K60 miniature circuit breaker — a 4-pole, 20 A thermal-magnetic MCB with a C-curve trip characteristic. It breaks 10,000 A Icn at 415 V AC, 50/60 Hz, per EN/IEC 60898-1, which is the standard governing residential and light commercial overcurrent protection. The C-curve (magnetic trip at 5 to 10 x In) suits it for mixed loads where moderate inrush — like small motors, fluorescent banks, or transformers — is present but not extreme. The 20,000-cycle electrical and mechanical endurance aligns with the duty cycle of a typical sub-distribution board, not a switch-disconnector cycled daily. IP20 finger-safe terminals keep it inside a panel; this is not a standalone outdoor breaker.

The Acti9 K60 series is Schneider's current-generation compact MCB range, so the A9KF71420BQ carries full manufacturer support and compliance documentation. Standards compliance includes EN/IEC 60898-1, pollution degree 2, overvoltage category II, and tropicalisation class 2 per IEC 60068-1 — meaning it handles 95% relative humidity at 55 °C without derating.

Integration notes

The toggle control is fixed-mount only — no rotary handle option on this variant. Earth-leakage protection is not integrated; if you need that, it's a separate RCBO or add-on Vigi module in the Acti9 range. Operating altitude is rated to 2000 m without derating. Above that, the dielectric withstand and cooling drop off — consult the thermal curve if your panel sits at elevation. The 70 mm depth is standard for this pole count; it leaves enough finger space behind a 100 mm deep enclosure.

Frequently asked questions

Where can I buy the A9KF71420BQ and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — it is not stocked on a retail shelf but is readily accessible through the supply channel.

What does the C-curve mean on this MCB?

The C-curve means the magnetic trip fires between 5 and 10 times the rated current (100 to 200 A for this 20 A breaker). That range covers moderate inrush from small motors, transformers, and capacitor banks without nuisance tripping, while still clearing hard faults fast enough for branch-circuit protection.

What is the closest alternative to the A9KF71420BQ in the Acti9 family?

Within the Acti9 K60 series, the closest sibling is the 4-pole, C-curve variant with a different current rating — for example, the A9KF71425BQ (25 A) or A9KF71416BQ (16 A). They share the same physical footprint, DIN pitch, breaking capacity, and terminal specs. The only difference is the thermal trip calibration. No pin-compatible alternative exists outside the Acti9 K60 range without re-checking the panel's short-circuit rating and curve coordination.

MPN
A9KF71420BQ