Schneider Electric A9L08300

Schneider Electric A9L08300 Acti9 iPRD8 Surge Arrester, 3P,

MPN A9L08300
Obsolete

Schneider Electric Acti9 iPRD8, Type 2+3 surge arrester, 3P, 350 V L/PE, 8 kA max discharge, clip-on DIN rail, white (RAL 9003).

$109.93 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9L08300 specifications
ParameterValue
Voltage400 V AC (+/- 10 %) at 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Storage temperature-40...85 °C
ColorWhite (RAL 9003)
Depth69 mm
Width54 mm
Height85 mm
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9L08300 is an Acti9 iPRD8 modular surge arrester — a Type 2 + 3 device with a pluggable MOV cartridge, rated 3P (three poles) for a 400 V AC TN-C or IT 230 V earthing system. It clamps line-to-PE surges at a maximum continuous voltage of 350 V L/PE and discharges up to 8 kA common mode (L/PE) on a Type 3 test wave, with a nominal discharge current of 2.5 kA. The open-circuit voltage (Uoc) is 10 kV for Type 3 common mode L/PE, and the voltage protection level (Up) stays under 1.2 kV. This is a distribution-network surge arrester, not a signal-line protector — it goes on the main or sub-distribution board to shunt lightning-induced and switching transients before they reach downstream equipment.

Clip-on DIN rail mounting (EN 60715) — occupies 6 modules of 9 mm pitch (54 mm total width). The housing is white RAL 9003, 85 mm tall and 69 mm deep. Tunnel-type terminals accept 2.5 to 25 mm² rigid or 4 to 16 mm² flexible conductors; tighten to 3.5 N·m. The IK03 impact rating (IEC 62262) means it withstands 0.35 J — standard for enclosed panel gear, not for exposed outdoor mounting. Operating temperature range is -25 to 60 °C, storage -40 to 85 °C, relative humidity 5 to 95 %. Operating altitude is limited to 2000 m.

Coordination with upstream overcurrent protection

The iPRD8 requires an associated disconnector — either a circuit breaker (iC60L, iC60N, or iC60H, 10 A curve C) or a gG fuse (25 A or 80 A, depending on the prospective fault current). The breaker's interrupting capacity (Icu) ranges from 10 kA to 25 kA, and the fuse's from 15 kA to 50 kA. This coordination ensures the surge arrether is safely disconnected if the MOV fails short-circuit. The temporary overvoltage (Ut) withstand is 337 V L/N for 5 seconds; above that, the device enters a safe failure mode at 422 V L/PE for 720 ms or 1200 V N/PE for 200 ms. Ground leakage current (Ipe) is 0.6 mA.