Schneider Electric Acti9 iPF8, Type 2+3 surge arrester, 2-pole (2P), 340 V MOV, 8 kA max discharge current, clip-on DIN rail mount, white (RAL 9003).

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9L15595 — Identification
ParameterValue
Product nameActi9 iPF
Product rangeActi9
Device short nameiPF8
Product / component typeSurge arrester
Device applicationDistribution
A9L15595 — Electrical
ParameterValue
Pole configuration2P
Rated operational voltage [Ue]230 V AC (+/- 10 %) at 50/60 Hz
A9L15595 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81.4 mm
Depth69 mm
Mounting modeClip-on (DIN rail)
Terminal connectionsTunnel type terminal (downside) 2.5...35 mm² Tunnel type terminal (upside) 2.5...35 mm²
Terminal tightening torque2.5 N.m
A9L15595 — Environmental
ParameterValue
Operating temperature range-25...60 °C
Storage temperature range-40...85 °C
Relative humidity5...90 %
A9L15595 — Approvals
ParameterValue
Standards / complianceEN 61643-11 IEC 61643-11

Product details

The Schneider Electric A9L15595 is an Acti9 iPF8 Type 2+3 surge arrester — a 2-pole (2P) MOV device rated for 230 V AC (+/- 10 %) at 50/60 Hz, with a maximum continuous operating voltage of 340 V common mode on L/PE and N/PE. The white (RAL 9003) housing is 81.4 mm tall and 69 mm deep.

Type 2+3 classification per EN 61643-11 and IEC 61643-11 means this arrester handles both main distribution board surge currents (Type 2, nominal 2.5 kA per mode) and equipment-level clamping (Type 3, open-circuit voltage 10 kV). The nominal discharge current is 2.5 kA common mode on L/PE and N/PE; the maximum single-shot discharge is 8 kA per mode, with a total discharge current of 15 kA. The voltage protection level stays under 1.1 kV on the Type 3 N/PE path — that's the let-through voltage the downstream gear sees. For a TN-C earthing system, the 2-pole configuration covers L and N to PE.

Mounts via clip-on DIN rail. Tunnel-type terminals top and bottom accept 2.5 to 35 mm² conductors; tighten to 2.5 N·m. Schneider specifies an associated circuit breaker — iC60N, iC60H, or iC60L, all 20 A curve C — to provide overcurrent backup and disconnection. The IK03 impact rating (IEC 62262) means it resists 0.35 J impacts, adequate for enclosed panel use. Relative humidity tolerance is 5 to 90 %.

Certified to EN 61643-11 and IEC 61643-11. Quality labels include OVE, KEMA-KEUR, and NF. The part carries no remote signalling contacts. No RoHS or REACH declaration is in this listing; request the manufacturer's declaration with the RFQ.

Frequently asked questions

What are the key ratings for the A9L15595?

It is a Type 2+3 surge arrester, 2-pole, 340 V maximum continuous voltage, 230 V AC rated operational voltage. Nominal discharge current is 2.5 kA per mode; maximum discharge is 8 kA per mode. Protection level is under 1.1 kV on the Type 3 path.

What circuit breaker should I use with the A9L15595?

Schneider specifies an associated circuit breaker from the iC60 range — iC60N, iC60H, or iC60L — all 20 A curve C, with interrupting capacities of 10 kA, 15 kA, and 25 kA respectively.

What compliance documentation does Schneider provide for the A9L15595?

The part carries EN 61643-11 and IEC 61643-11 certification, with quality marks OVE, KEMA-KEUR, and NF. RoHS and REACH declarations are not in this listing; request them from the manufacturer at the time of ordering.