Schneider Electric A9L16557 — 1-Pole MCB (DIN Rail)

A9L16557 Acti9 iPRD Surge Arrester, Type 2, 65 kA, 1P+N

MPNA9L16557
Obsolete

Schneider Electric Acti9 iPRD Type 2 surge arrester, 1P+N, 340 V Uc, 65 kA Imax, with remote signalling, white (RAL 9003), clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9L16557 — Identification
ParameterValue
Product nameActi9 iPRD
Product / component typeSurge arrester with pluggable cartridge
Device short nameiPRD
Poles description1P + N
Device applicationDistribution
A9L16557 — Electrical & Protection
ParameterValue
Rated operational voltage (Ue)230 V AC (+/- 10 %) at 50/60 Hz
A9L16557 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminal (downside) 2.5...35 mm² Tunnel type terminal (upside) 2.5...35 mm²
Mounting modeClip-on (DIN rail)
Width36 mm
Height81 mm
Depth69 mm
Tightening torque (by circuit)2.5 N.m
A9L16557 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
A9L16557 — Approvals
ParameterValue
Conformity standardsEN 61643-11 IEC 61643-11

Product details

The Schneider Electric A9L16557 is an Acti9 iPRD Type 2 surge arrester in a 1P+N configuration, rated for 230 V AC (+/- 10 %) operational voltage with a maximum continuous operating voltage (Uc) of 340 V on L/N and L/PE, and 260 V on N/PE. It handles a nominal discharge current (In) of 20 kA per mode and a maximum discharge current (Imax) of 65 kA across common and differential modes. The protection level (Up) is <1.5 kV for Type 2 L/N. This unit includes a remote signalling contact (1 C/O, 0.25 A/250 V AC) for status monitoring.

The Type 2 classification (per EN 61643-11 / IEC 61643-11) means this arrester is designed for the main distribution board or sub-distribution board in a TN-S or TT earthing system — it handles induced surge currents from switching or indirect lightning strikes, not direct strikes (that is Type 1 territory). The 65 kA Imax tells you the maximum single-surge current it can safely divert without failing; the 20 kA In is the rated current it can handle repeatedly over its life. The 1P+N pole configuration covers a single-phase line and neutral, common in small commercial or residential final circuits. The MOV + GDT hybrid technology combines a metal-oxide varistor for fast clamping with a gas discharge tube for higher energy handling and reduced leakage.

Width is 36 mm (2 modular spaces at 9 mm pitch each, 4 pitches total). Tunnel-type terminals accept 2.5 to 35 mm² conductors on both top and bottom, with a tightening torque of 2.5 N.m. The white (RAL 9003) housing matches the Acti9 family aesthetic for panel builds. The remote signalling contact allows integration with a PLC or building management system for remote status of the surge protection element.

Designed and tested to EN 61643-11 and IEC 61643-11 for Type 2 surge protective devices. The enclosure carries an IK03 impact protection rating per IEC 62262. Relative humidity range is 5 to 90 %. Operating altitude is limited to 2000 m.

Frequently asked questions

Who supplies A9L16557 and how is it quoted for volume purchases?

The A9L16557 is sourced through independent distribution channels. It is quoted to order against an RFQ; availability and current pricing are confirmed at the time of quote.

What is A9L16557's listed depth (69 mm) on this component line?

The A9L16557 has a depth of 69 mm.

What is A9L16557's listed width (36 mm) on this component line?

The A9L16557 has a width of 36 mm.

MPN