Schneider Electric A9L16576 — 1-Pole MCB (DIN Rail)

Schneider Electric A9L16576 Acti9 iPRD8 Surge Arrester, 1P,

MPNA9L16576
Obsolete

Schneider Electric Acti9 iPRD8, Type 2+3 surge arrester, 1 pole, 340 V AC, 8 kA max discharge, clip-on DIN rail, white (RAL 9003).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9L16576 — Identification
ParameterValue
Product nameActi9 iPRD
Product / component typeSurge arrester with pluggable cartridge
Device short nameiPRD8
Poles description1P
Device applicationDistribution
A9L16576 — Electrical & Protection
ParameterValue
Rated operational voltage (Ue)230 V AC (+/- 10 %) at 50/60 Hz
A9L16576 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminal (downside) 2.5...35 mm² Tunnel type terminal (upside) 2.5...35 mm²
Mounting modeClip-on (DIN rail)
Width18 mm
Height81 mm
Depth69 mm
Tightening torque (by circuit)2.5 N.m
A9L16576 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
A9L16576 — Approvals
ParameterValue
Conformity standardsEN 61643-11 IEC 61643-11

Product details

The Schneider Electric A9L16576 is an Acti9 iPRD8 Type 2+3 surge arrester, a 1-pole MOV-based unit rated for 230 V AC (+/- 10%) at 50/60 Hz with a maximum continuous operating voltage of 340 V (L/PE, N/PE).

Rated for a nominal discharge current of 2.5 kA (L/PE, N/PE) and a maximum discharge current of 8 kA (L/PE) — that's the surge it can safely divert in a lightning or switching transient. The open-circuit voltage (Uoc) is 10 kV for Type 3 common mode L/PE, and the voltage protection level (Up) stays under 1 kV for Type 3 L/PE, meaning sensitive downstream electronics see a clamped surge well within typical equipment withstand limits. As a Type 2 + 3 arrester, it handles both main distribution board surges (Type 2, 8/20 µs wave) and fine protection at the sub-distribution or equipment level (Type 3, combined wave). The MOV technology gives fast response with no follow current. The unit is certified to EN 61643-11 and IEC 61643-11, carries KEMA-KEUR, OVE, and NF quality marks, and has an IK03 impact rating per IEC 62262 — enough for standard panel environments. Operating temperature range is -25 to 60 °C, storage -40 to 85 °C, with 5-90% relative humidity and a 2000 m altitude limit.

Clip-on DIN rail mounting, 18 mm wide, 81 mm high, 69 mm deep. Tunnel-type terminals top and bottom accept 2.5 to 35 mm² conductors; tightening torque is 2.5 N·m. The white (RAL 9003) housing fits standard Acti9 enclosures.

This part is marked obsolete by the manufacturer.

Frequently asked questions

How do I get current pricing and availability for A9L16576?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.

What is the closest alternative to A9L16576 in the Acti9 family?

No official successor order code is listed. For a functionally similar Type 2+3 1P surge arrester in the Acti9 range, consult the current Acti9 iPRD catalog — the replacement will share the same DIN-rail footprint and terminal capacity.

What compliance documentation does this surge arrester carry?

It is certified to EN 61643-11 and IEC 61643-11, with quality marks KEMA-KEUR, OVE, and NF. The operating standards and ratings are documented in the Schneider Electric datasheet.

MPN
A9L16576