Schneider Electric A9L16617 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9L16617 Acti9 iQuick PF Type 2 Surge Arr

MPNA9L16617
Obsolete

Schneider Electric Acti9 iQuick PF, Type 2 surge arrester, 1P+N, 275 V Uc, 10 kA max discharge, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9L16617 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)230 V AC (+/- 10 %) at 50/60 Hz
Poles description1P + N
A9L16617 — Identification
ParameterValue
Product nameActi9 PF
Product / component typeSurge arrester
Device short nameiQuick PF
A9L16617 — Mechanical
ParameterValue
Mounting modeClip-on (DIN rail)
Width in 9 mm modules4
Terminal connectionsTunnel type terminal (L/N) 1...16 mm² rigid Tunnel type terminal (L/N) 1...10 mm² flexible Tunnel type terminal (ground) 6...25 mm² rigid Tunnel type terminal (ground) 6...16 mm² flexible with ferrule
Terminal tightening torque2 N.m
Width36 mm
Height109.7 mm
Depth72.1 mm
A9L16617 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...85 °C
Relative humidity5...95 %
A9L16617 — Approvals
ParameterValue
StandardsEN 61643-11:2012 IEC 61643-11:2011

Product details

Type 2 Surge Arrester for TN-S and TT Systems

The Schneider Electric A9L16617 is a Type 2 surge arrester from the Acti9 iQuick PF series, designed for 1P+N distribution networks at 230 V AC (+/- 10 %) 50/60 Hz. It uses a hybrid MOV + GDT technology to clamp transient overvoltages, with a maximum continuous operating voltage (Uc) of 275 V in both common and differential modes. Rated for a nominal discharge current (In) of 5 kA differential (L/N) and 10 kA common mode (N/PE), with a maximum discharge current (Imax) of 10 kA on both paths. The voltage protection level (Up) is held below 1.5 kV for Type 2 L/N paths, which is the key figure for ensuring downstream equipment withstands the let-through voltage. The follow current (Ifi) is specified at 0.1 kA common mode N/PE.

Temporary Overvoltage and Earthing Compatibility

This arrester is rated for TN-S and TT earthing systems. The temporary overvoltage (Ut) withstand is 337 V L/N for 5 seconds, 1200 V N/PE for 200 ms in safe failure mode, and 442 V L/PE for 5 seconds — important for networks where a neutral shift or loss of neutral can occur. Ground residual current (Ipe) is 1 mA, and the device is rated for an IK03 impact protection level per IEC 62262, meaning it withstands a 0.35 J impact — sufficient for enclosed panel mounting.

The housing is white (RAL 9003). Tunnel-type terminals accept 1 to 16 mm² rigid (L/N), 1 to 10 mm² flexible (L/N), and 6 to 25 mm² rigid (ground).

Frequently asked questions

What are the key discharge current ratings for A9L16617?

Nominal discharge current (In) is 5 kA differential (L/N) and 10 kA common mode (N/PE). Maximum discharge current (Imax) is 10 kA on both paths.

What earthing systems is the A9L16617 compatible with?

It is rated for TN-S and TT earthing systems.

What is the voltage protection level (Up) of the A9L16617?

The maximum voltage protection level (Up) is less than 1.5 kV for Type 2 L/N paths.

How do I get pricing and availability for the A9L16617?

The A9L16617 is sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time.