Schneider Electric A9L1C602 — Fuses & Fuse Holders

A9L1C602 Acti9 iPRD1 C25r Surge Cartridge, Type 1+2, 100 kA

MPNA9L1C602
Active

Schneider Electric Acti9 iPRD1 C25r Type 1+2 surge protection cartridge, 100 kA nominal discharge, <100 ns response, 240 V AC, 2-pole wide, plug-in mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

A9L1C602 — Identification
ParameterValue
Product / component typeCartridge
Product rangeActi9
A9L1C602 — Ratings
ParameterValue
Rated operational voltage (Ue)240 V AC 50/60 Hz
A9L1C602 — Environmental
ParameterValue
Storage ambient temperature-40...85 °C
IP protection ratingIP20
A9L1C602 — Mechanical
ParameterValue
Mounting supportInto SPD module
Width18 mm
Depth73.5 mm
Height45 mm
A9L1C602 — Approvals
ParameterValue
Standards / approvalsIEC 61643-11:2011 EN 61643-11:2012 EN 61643-11:2018/A11
A9L1C602 — Specifications
ParameterValue
Surge arrester class typeType 1 + 2
Device short nameiPRD1 C25r
Surge arrester typeElectrical distribution network
A9L1C602 — Electrical
ParameterValue
Nominal discharge currentCommon mode: 100 kA (N/PE)
Maximum discharge currentCommon mode: 150 kA N/PE
Maximum [Up] voltage protection levelCommon mode <1.5 kV N/PE

Product details

The Schneider Electric A9L1C602 is an Acti9 iPRD1 C25r Type 1+2 surge protection cartridge rated for 100 kA nominal discharge current (common mode) and a maximum of 150 kA (N/PE), with an impulse current Iimp of 100 kA per the Type 1 classification. It responds in under 100 ns, clamping the voltage protection level to below 1.5 kV (common mode).

The Type 1+2 classification means this cartridge handles both direct lightning strikes (Type 1, 10/350 µs waveform) and switching transients (Type 2, 8/20 µs) in a single unit — a common requirement for main distribution boards where the service entrance and sub-distribution protection are combined. The 100 kA nominal discharge current (In) is the rating for repeated surges; the 150 kA maximum (Imax) is the single-event survival limit. A 100 kA Iimp (Type 1 impulse current) confirms it can safely divert a direct lightning stroke's energy per IEC 61643-11. The <1.5 kV protection level (Up) means downstream equipment rated for 1.5 kV or higher is protected; if your load's impulse withstand (Uw) is lower, you need an additional Type 3 stage. The 305 V maximum continuous operating voltage (Uc) allows it to ride through normal grid fluctuations without degrading, and the 1200 V temporary overvoltage (Ut) withstand for 200 ms handles fault conditions on the N/PE path.

Deployment context

At 18 mm wide (2 x 9 mm pitches), it occupies a single modular space, leaving room for other protection or metering modules in the same row.

Frequently asked questions

Where can I buy A9L1C602 and how is it quoted?

The A9L1C602 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the response time of A9L1C602?

The response time is under 100 ns, which means it clamps surges before they can damage downstream equipment.

What standards does A9L1C602 comply with?

It complies with IEC 61643-11:2011, EN 61643-11:2012, and EN 61643-11:2018/A11, and carries VDE quality label certification.