Schneider Electric A9L20200 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9L20200 Acti9 iPRD20 Type 2 Surge Arrest

MPNA9L20200
Active

Schneider Electric Acti9 iPRD20 Type 2 surge arrester, 2P, 350 V, 20 kA max discharge, clip-on DIN rail, white (RAL 9003).

$83.24Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9L20200 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)230 V AC (+/- 10 %) at 50/60 Hz
Poles description2P
A9L20200 — Identification
ParameterValue
Product nameActi9 iPRD
Product / component typeSurge arrester with pluggable cartridge
Device short nameiPRD20
A9L20200 — Mechanical
ParameterValue
Mounting modeClip-on (DIN rail)
Width in 9 mm modules4
Terminal connectionsTunnel type terminal (downside) 2.5...35 mm² Tunnel type terminal (upside) 2.5...35 mm²
Terminal tightening torque2.5 N.m
Width36 mm
Height85 mm
Depth69 mm
A9L20200 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
Relative humidity5...95 %
Operating altitude2000 m
A9L20200 — Approvals
ParameterValue
StandardsEN 61643-11:2012 IEC 61643-11:2011

Product details

The Schneider Electric A9L20200 is an Acti9 iPRD20 Type 2 surge arrester, 2-pole, rated 230 V AC (+/- 10%) at 50/60 Hz, with a maximum continuous operating voltage of 350 V common mode per the datasheet. It uses MOV technology and clips onto a DIN rail — standard panel integration for distribution boards.

Nominal discharge current is 5 kA (common mode L/PE and N/PE); maximum discharge current is 20 kA (common mode). That 20 kA rating tells you this unit can safely divert a direct lightning-induced surge up to that level without failing short — it's sized for main distribution panels in TN-C-S earthing systems, not sub-panel or device-level protection. The Type 2 classification per EN 61643-11:2012 and IEC 61643-11:2011 means it's tested for the main distribution board location, handling the bulk of surge energy before it reaches sensitive loads downstream. The protection level (Up) is under 1.1 kV common mode — within tolerance for typical 230 V equipment impulse withstand. Temporary overvoltage (Ut) is 337 V L/N for 5 s withstand, and 1200 V N/PE for 200 ms safe failure mode — the MOV will thermally disconnect rather than rupture under sustained overvoltage. Ground residual current is 0.003 mA to 0.6 mA, which keeps leakage well below nuisance RCD trip thresholds.

Clip-on DIN rail mounting, 36 mm wide (2 x 18 mm modular pitches), 69 mm deep, 85 mm high. Tunnel-type terminals accept 2.5 to 35 mm² on both top and bottom — solid or stranded copper, torque to 2.5 N·m. The white (RAL 9003) housing blends into standard distribution board layouts. Operating temperature range is -25 to 60 °C, storage -40 to 85 °C, with relative humidity 5 to 95%. IK03 impact rating per IEC 62262 means it withstands 0.35 J impacts — adequate for enclosed panel installation, not for exposed locations.

Frequently asked questions

What is A9L20200's listed depth and width?

Depth is 69 mm, width is 36 mm (2 modular pitches).

What compliance documentation does this brand provide for A9L20200?

The product carries NF and KEMA-KEUR quality labels and complies with EN 61643-11:2012 and IEC 61643-11:2011 standards.

Where can I buy A9L20200 and how is it quoted?

The A9L20200 is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.