Schneider Electric A9L2F640 — Fuses & Fuse Holders

Schneider Electric A9L2F640 Acti9 iPRD F40r Type 2+3 Surge A

MPNA9L2F640
Active

Schneider Electric Acti9 iPRD F40r, Type 2+3 surge arrester, 3P+N, 20 kA nominal discharge current, 25 kA short-circuit withstand, clip-on DIN rail mount, white (RAL 9003).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9L2F640 — Identification
ParameterValue
Product nameActi9 iPRD
Product / component typeSurge arrester with pluggable cartridge
Poles3P + N
ApplicationDistribution
Product rangeActi9
A9L2F640 — Ratings
ParameterValue
Rated operational voltage (Ue)230/400 V AC at 50/60 Hz
A9L2F640 — Environmental
ParameterValue
Operating ambient temperature-40...85 °C
IP protection ratingIP20 with cartridges fitted and device wired
IK impact protection ratingIK05
A9L2F640 — Mechanical
ParameterValue
Width72 mm
Depth70 mm
Height105 mm
Tightening torquePower circuit: 4.5 N.m
A9L2F640 — Approvals
ParameterValue
Standards / approvalsIEC 61643-11:2011 EN 61643-11:2012 EN 61643-11:2018/A11
A9L2F640 — Specifications
ParameterValue
Surge arrester class typeType 2 + 3
Device short nameiPRD F40r
Surge arrester typeElectrical distribution network
A9L2F640 — Electrical
ParameterValue
Nominal discharge currentDifferential mode: 20 kA (L/N) Common mode: 40 kA (N/PE)
Maximum discharge currentDifferential mode: 40 kA L/N Common mode: 65 kA N/PE
Maximum [Up] voltage protection levelDifferential mode Common mode <1.5 kV N/PE

Product details

The Schneider Electric A9L2F640 is an Acti9 iPRD F40r surge arrester — a Type 2+3 unit with pluggable cartridges, designed for the electrical distribution network. It uses MOV + GDT technology to clamp both differential-mode (L/N) and common-mode (N/PE) transients, with a nominal discharge current of 20 kA per mode and a maximum of 40 kA (L/N) / 65 kA (N/PE). Rated for 230/400 V AC at 50/60 Hz, it handles TT and TN-S earthing systems, with a temporary overvoltage withstand of 337 V L/N for 5 seconds and 442 V L/N for 120 minutes in safe failure mode. The response time is under 25 ns for L/N paths and under 100 ns for N/PE — fast enough to clip most incoming surges before they reach downstream equipment.

Clip-on DIN rail mounting (72 mm wide, 105 mm high, 70 mm deep) fits standard distribution board spacing — 8 modules of 9 mm pitch. IP20 with cartridges fitted and wired; IK05 impact resistance. Power terminals accept 2.5–35 mm² solid/stranded cable; earthing terminal goes up to 35 mm² solid. Wire stripping lengths: 18 mm for power and earth, 10 mm for remote signalling.

Compliant with IEC 61643-11:2011, EN 61643-11:2012, and EN 61643-11:2018/A11 — the governing standards for low-voltage surge protective devices. The remote signalling contact is rated 1 A / 250 V AC and 0.5 A at 24/48 V DC for connection to a PLC or alarm panel.

Frequently asked questions

Where can I buy A9L2F640 and how do I get a price?

The A9L2F640 is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time, no obligation.

What is A9L2F640's listed depth?

The A9L2F640 has a depth of 70 mm, with a width of 72 mm and height of 105 mm, occupying 8 modules of 9 mm pitch on DIN rail.

What compliance documentation does this brand provide for A9L2F640?

The A9L2F640 is certified to IEC 61643-11:2011, EN 61643-11:2012, and EN 61643-11:2018/A11. The manufacturer provides the relevant declarations and test reports for these standards.