Schneider Electric A9L65101 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9L65101 Acti9 iPRD65r Type 2 Surge Arres

MPNA9L65101
Active

Schneider Electric Acti9 iPRD65r, Type 2 surge arrester, 1P, 350 V, 65 kA max discharge, with remote signalling, clip-on DIN rail mount.

$66.41Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9L65101 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)230 V AC (+/- 10 %) at 50/60 Hz
Poles description1P
A9L65101 — Identification
ParameterValue
Product nameActi9 iPRD
Product / component typeSurge arrester with pluggable cartridge
Device short nameiPRD65r
A9L65101 — Mechanical
ParameterValue
Mounting modeClip-on (DIN rail)
Width in 9 mm modules2
Terminal connectionsTunnel type terminal (downside) 2.5...35 mm² Tunnel type terminal (upside) 2.5...35 mm²
Terminal tightening torque2.5 N.m
Width18 mm
Height85 mm
Depth69 mm
A9L65101 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
Relative humidity5...95 %
Operating altitude2000 m
A9L65101 — Approvals
ParameterValue
StandardsEN 61643-11:2012 IEC 61643-11:2011

Product details

The A9L65101: The Type 2 classification (per EN 61643-11:2012 and IEC 61643-11:2011) means this unit is designed for installation on sub-distribution boards to clamp induced surge voltages from switching or indirect lightning strikes — it is not a primary service entrance protector (Type 1). With a maximum continuous operating voltage Uc of 350 V (L/PE and N/PE), it is compatible with 230/400 V TN and IT networks where the line-to-neutral voltage stays under 350 V. The temporary overvoltage (Ut) withstand of 337 V L/N for 5 seconds and safe failure mode at 1200 V N/PE for 200 ms gives the coordination engineer a defined failure characteristic to design selectivity around. The protection level Up is stated as <1.5 kV (common mode L/PE). That is the voltage the arrester lets through to the protected equipment during a discharge event. For downstream equipment with a rated impulse withstand (Uimp) of 2.5 kV or higher, this provides adequate margin. The 1 SD (1 C/O) remote signalling contact (0.25 A/250 V AC) allows the panel to report a failed cartridge to a PLC or building management system — useful for sites where the arrester is in a locked or inaccessible distribution board.

The unit clips onto a DIN rail (EN 60715). Its footprint is 18 mm wide (1 module width) by 85 mm high by 69 mm deep, occupying two 9 mm pitches. The tunnel-type terminals on both top and bottom accept 2.5 to 35 mm² conductors; tightening torque is 2.5 N·m. For a distribution board already populated with Acti9 MCBs, the iPRD65r shares the same form factor and can be mounted directly adjacent, keeping the busbar arrangement clean.

Frequently asked questions

What is the closest alternative to A9L65101 in the Acti9 iPRD family?

Within the Acti9 iPRD65r series, the A9L65101 is the 1P variant at 350 V with remote signalling. The 2P (A9L65102) and 3P (A9L65103) variants share the same Type 2, 65 kA max discharge, and MOV technology but add poles for three-phase networks. The choice is driven by the number of protected phases, not by any functional difference in surge performance per pole.

How do I get current pricing and availability for A9L65101?

The A9L65101 is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current pricing and availability; stock levels and lead time are confirmed at the time of quotation.