Skip to main content
Schneider Electric A9N16202 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N16202 Acti9 xID RCCB, 25 A, 300 mA, 2P

MPNA9N16202
Active

Schneider Electric Acti9 xID, residual current circuit breaker (RCCB), 2P, 25 A, 300 mA, Type AC, 230-240 V AC, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N16202 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Local signalling / indicationON, OFF, fault trip
A9N16202 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)230...240 V AC 50 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durability4000 cycles
Mechanical durability (operating cycles)4000 cycles
A9N16202 — Identification
ParameterValue
Product nameActi9 xID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short namexID
A9N16202 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height81 mm
Depth75 mm
A9N16202 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9N16202 — Approvals
ParameterValue
StandardsEN 61008-2-1 IEC 61008-2-1 EN/IEC 61008-1

Product details

The Schneider Electric A9N16202 is an Acti9 xID residual current circuit breaker (RCCB) — a 2-pole, Type AC device rated for 25 A continuous load with 300 mA earth-leakage sensitivity. It operates on a 230-240 V AC, 50 Hz network and clips onto a standard DIN rail.

The 25 A rated current (In) sizes the RCCB for a 25 A feeder — common for lighting sub-circuits, general socket groups, or small appliance loads. The 300 mA sensitivity (IΔn) is less sensitive than the 30 mA type used for personal shock protection; it is selected where the priority is fire protection and equipment leakage tolerance, such as on circuits with multiple connected loads that have inherent leakage. For those, a Type A or Type B RCCB would be required. The rated breaking and making capacity is 500 A per EN/IEC 61008-1. In a domestic or light commercial distribution board, this is adequate for the prospective fault current typically seen downstream of a 63 A or 100 A main switch.

The 2-pole device occupies 4 modules of 9 mm pitch (36 mm total width). Neutral is on the left. Tunnel-type terminals accept 1-35 mm² rigid or 1-25 mm² flexible conductors; tighten to 3.5 N·m.

Frequently asked questions

How do I get current pricing and availability for A9N16202?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time — the part is sourced to order through independent distribution channels.

What is A9N16202's listed depth?

The A9N16202 has a depth of 75 mm, a width of 36 mm (4 x 9 mm pitches), and a height of 81 mm.

What compliance documentation does this RCCB carry?

The A9N16202 is certified to EN 61008-2-1 and IEC 61008-2-1, and meets the general requirements of EN/IEC 61008-1. It is tropicalised to class 2 per IEC 60068-1. The IP20 rating is for enclosed installation only.

MPN
A9N16202