Skip to main content
Schneider Electric A9N16205 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N16205 Acti9 xID RCCB, 40 A, 100 mA, 2P

MPNA9N16205
Active

Schneider Electric Acti9 xID RCCB, 2P, 40 A, 100 mA, Type AC, 230-240 V AC, DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N16205 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Local signalling / indicationON, OFF, fault trip
A9N16205 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)230...240 V AC 50 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durability4000 cycles
Mechanical durability (operating cycles)4000 cycles
A9N16205 — Identification
ParameterValue
Product nameActi9 xID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short namexID
A9N16205 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height81 mm
Depth75 mm
A9N16205 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9N16205 — Approvals
ParameterValue
StandardsEN/IEC 61008-1 EN 61008-2-1 IEC 61008-2-1

Product details

The Schneider Electric A9N16205 is an Acti9 xID residual current circuit breaker (RCCB) — a 2-pole, Type AC device rated at 40 A with 100 mA earth-leakage sensitivity. The Type AC classification means it detects sinusoidal AC earth faults only, so it's suited for general-purpose circuits where no pulsed DC or mixed-frequency leakage is expected — think lighting, socket outlets, and resistive loads in commercial or residential distribution boards.

The 40 A rated current (In) sets the continuous load this RCCB can carry without tripping on overload — sized for a 40 A submain or final circuit. The 100 mA sensitivity is less sensitive than the common 30 mA type; it's chosen where nuisance tripping from cable capacitance or equipment leakage is a concern, or where the installation standard allows a higher threshold (e.g., fire-protection RCCBs or circuits feeding fixed equipment).

Integration notes

Neutral is on the left — verify busbar orientation if linking to an adjacent MCB or RCCB. Tunnel terminals accept 1-35 mm² rigid or 1-25 mm² flexible; strip 14 mm, torque to 3.5 N·m. Padlocking provision allows lockout for isolation, and the toggle gives clear ON/OFF/trip indication.

Frequently asked questions

Where can I buy the A9N16205 and how is it quoted?

The A9N16205 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of the A9N16205?

The A9N16205 is a 2-pole Type AC RCCB rated at 40 A with 100 mA earth-leakage sensitivity, operating at 230-240 V AC, 50 Hz, with a 500 A breaking capacity per EN/IEC 61008-1.

What compliance standards does the A9N16205 meet?

The A9N16205 complies with EN/IEC 61008-1, EN 61008-2-1, and IEC 61008-2-1. It is tropicalised to class 2 per IEC 60068-1.

MPN
A9N16205