A9N16210 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Local signalling / indicationON, OFF, fault trip
A9N16210 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)230...240 V AC 50 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durability4000 cycles
Mechanical durability (operating cycles)4000 cycles
A9N16210 — Identification
ParameterValue
Product nameActi9 xID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short namexID
A9N16210 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height81 mm
Depth75 mm
A9N16210 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9N16210 — Approvals
ParameterValue
StandardsIEC 61008-2-1 EN/IEC 61008-1 EN 61008-2-1

Product details

The Schneider Electric A9N16210 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 xID range, rated 63 A with 300 mA earth-leakage sensitivity, Type AC. The 300 mA sensitivity suits general-purpose earth-leakage protection where a higher trip threshold avoids nuisance tripping from normal leakage in fixed equipment or long cable runs. Type AC detection responds to sinusoidal AC residual currents only.

Rated 63 A continuous at 230-240 V AC, this RCCB handles the full load current of a typical main distribution board or submain feeding multiple final circuits. Insulation voltage rated 500 V AC gives headroom above the operating voltage, so the internal clearances and creepage distances are designed for that higher stress. Pollution degree 2 (non-conductive pollution only, occasional condensation) is the standard for enclosed electrical panels. Mechanical and electrical durability both rated 4000 cycles — this is a protection device, not a daily-switching contactor, so the cycle count reflects the expected life in a distribution board where it operates only on fault or periodic test.

Wire stripping length 14 mm for top or bottom connection. The padlocking device allows locking in the OFF position for isolation during maintenance — the contact position indicator confirms the state visually.

Standards and lifecycle

Designed to IEC 61008-1 and EN 61008-2-1, the main standards for residual current circuit breakers without integral overcurrent protection. IP20 rated for finger-safe installation inside a panel enclosure. Tropicalisation level 2 per IEC 60068-1 for damp-heat environments.