Schneider Electric A9N16212 — Residual Current Breakers (RCCB/RCBO)

A9N16212 Acti9 xID RCCB 80A 30mA 2P Type AC

MPNA9N16212
Active

Schneider Electric Acti9 xID A9N16212, 2-pole residual current circuit breaker (RCCB), 80 A, 30 mA Type AC, 230-240 V AC, DIN rail clip-on.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N16212 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Local signalling / indicationON, OFF, fault trip
A9N16212 — Electrical Ratings
ParameterValue
Rated current (In)80 A
Rated operational voltage (Ue)230...240 V AC 50 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durability4000 cycles
Mechanical durability (operating cycles)4000 cycles
A9N16212 — Identification
ParameterValue
Product nameActi9 xID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short namexID
A9N16212 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height81 mm
Depth75 mm
A9N16212 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9N16212 — Approvals
ParameterValue
StandardsIEC 61008-2-1 EN/IEC 61008-1 EN 61008-2-1

Product details

80 A RCCB for panel builders — what the ratings mean

Type AC covers the sine-wave faults most common in resistive and simple inductive loads; it does not detect pulsating DC or high-frequency residuals (those call for Type A or Type F). Mounts via clip-on to DIN rail (35 mm per EN 60715), occupying 4 x 9 mm pitches (36 mm width). The tunnel-type terminals accept 1…35 mm² rigid or 1…25 mm² flexible cable; tighten to 3.5 N·m.

Designed and tested to IEC 61008-1, EN 61008-1, and IEC 61008-2-1 — the core standards for residual current operated circuit-breakers without integral overcurrent protection. Pollution degree 2 (normal industrial/domestic environment). IP20 finger-safe terminals; install inside a distribution board or enclosure rated for the ambient conditions.

Frequently asked questions

Where can I buy A9N16212 and how do I get a price?

The A9N16212 is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the closest alternative to A9N16212 in the Acti9 family?

Within the Acti9 xID range, the closest alternative is a different sensitivity or pole count variant — for example, a 30 mA Type A 2P RCCB for circuits with electronic loads that generate pulsating DC fault currents. The mechanical footprint (36 mm width, DIN rail clip-on) and terminal specifications are identical across the xID family, so swapping requires only verifying the earth-leakage protection class and rated current match the circuit design.

What compliance documentation does Schneider provide for A9N16212?

The A9N16212 carries CE marking and is designed to meet IEC 61008-1, EN 61008-1, and IEC 61008-2-1. Standard documentation includes the declaration of conformity and the product datasheet. RoHS and REACH compliance declarations are available from Schneider Electric's documentation portal.

MPN
A9N16212