Schneider Electric A9N16214 — Residual Current Breakers (RCCB/RCBO)

A9N16214 Acti9 xID RCCB 80A 300mA 2P Type AC

MPNA9N16214
Obsolete

Schneider Electric Acti9 xID, Residual Current Circuit Breaker (RCCB), A9N16214, 80 A, 300 mA, 2P, Type AC, 230-240 V AC, clip-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N16214 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Local signalling / indicationON, OFF, fault trip
A9N16214 — Electrical Ratings
ParameterValue
Rated current (In)80 A
Rated operational voltage (Ue)230...240 V AC 50 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durability4000 cycles
Mechanical durability (operating cycles)4000 cycles
A9N16214 — Identification
ParameterValue
Product nameActi9 xID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short namexID
A9N16214 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height81 mm
Depth75 mm
A9N16214 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9N16214 — Approvals
ParameterValue
StandardsIEC 61008-2-1 EN/IEC 61008-1 EN 61008-2-1

Product details

The Schneider Electric A9N16214 is a 2-pole Residual Current Circuit Breaker (RCCB) from the Acti9 xID series, rated 80 A with 300 mA earth-leakage sensitivity. It protects against earth faults in AC circuits at 230-240 V, 50 Hz. The 300 mA trip threshold suits it for general distribution protection rather than personal shock protection — it's sized to catch insulation faults and prevent fire risk on submain or feeder circuits, not for socket-outlet final circuits where 30 mA is the norm.

Neutral on the left. Tunnel terminals accept 1-35 mm² rigid or 1-25 mm² flexible cable; strip 14 mm and torque to 3.5 N.m.

If the downstream load includes electronics with rectifiers, a Type A or Type B RCCB would be needed instead. Rated insulation voltage 500 V AC, operational voltage 230-240 V AC. The 80 A continuous rating and 4000-cycle electrical/mechanical durability are typical for a distribution RCCB in this form factor — it's not a heavy-duty switching device, but a protective device that trips infrequently under fault conditions.

Frequently asked questions

What is the earth-leakage sensitivity and protection class?

300 mA sensitivity, Type AC. This detects sinusoidal AC residual currents only. For circuits with non-sinusoidal or DC fault currents, a Type A or Type B device is required.

Where can I buy A9N16214 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers are published here.

What compliance documentation does this RCCB carry?

It complies with IEC 61008-1, IEC 61008-2-1, and EN 61008-2-1. Tropicalisation per IEC 60068-1. Pollution degree 2. Suitability for isolation is marked on the device.

MPN
A9N16214