Schneider Electric A9N16246 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N16246 Acti9 xID RCCB, 63A 300mA Type A

MPNA9N16246
Active

Schneider Electric Acti9 xID RCCB, A9N16246, 2P, 63 A, 300 mA Type A-SI Super Immunised, selective, 230-240 V AC, DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N16246 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delaySelective
Local signalling / indicationON, OFF, fault trip
A9N16246 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)230...240 V AC 50 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durability4000 cycles
Mechanical durability (operating cycles)4000 cycles
A9N16246 — Identification
ParameterValue
Product nameActi9 xID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short namexID
A9N16246 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height81 mm
Depth75 mm
A9N16246 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9N16246 — Approvals
ParameterValue
StandardsIEC 61008-2-1 EN 61008-2-1 EN/IEC 61008-1

Product details

The Schneider Electric A9N16246 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 xID family, rated at 63 A with a 300 mA earth-leakage sensitivity. It's a Type A-SI (Super Immunised) device with a selective time delay, meaning it's built for circuits where nuisance tripping from high-frequency harmonics or surge currents is a concern — common on supply lines feeding VFDs, UPS systems, or welding equipment. The selective delay coordinates with downstream RCCBs so only the faulted branch trips, keeping the rest of the installation live.

The 63 A continuous rating (In) covers the full load of a typical sub-distribution board feeding multiple final circuits — sized for a 3-phase incomer on a residential or light commercial DB. The 300 mA sensitivity is the standard for fire protection (not personal shock protection), so this RCCB goes upstream of the 30 mA devices on socket outlets. The Type A-SI classification handles pulsating DC fault currents and is immunised against unwanted tripping from 50 Hz harmonics and transient surges up to several kA — the SI suffix means it passes the 3 kA surge-withstand test per IEC 61008-1 without tripping. The selective time delay (marked "S") introduces a deliberate 40-150 ms delay before tripping, allowing downstream 30 mA RCCBs to clear first; if they don't, this unit backs them up.

Tunnel terminals accept 1-35 mm² rigid or 1-25 mm² flexible copper — strip 14 mm, torque to 3.5 N·m. The 18 mm phase-to-phase pitch matches the Acti9 busbar system for a clean feed through a distribution board. IP20 rated for enclosure use only; no washdown rating.

Standards and environmental

Designed and certified to IEC 61008-1, EN 61008-1, and EN 61008-2-1 — the core RCCB standards for residual current protection. Storage range -40 to 85 °C covers most site conditions. Pollution degree 2 (normal, non-condensing). Isolation suitability is confirmed, with a visible contact position indicator and padlocking provision for lockout/tagout.

Frequently asked questions

What is the A9N16246 used for?

It is a 2-pole residual current circuit breaker (RCCB) used for earth-leakage protection in AC networks, typically installed upstream of final sub-circuits in distribution boards. The 300 mA sensitivity and selective time delay make it suitable for fire protection and coordination with downstream 30 mA RCCBs.

What does Type A-SI Super Immunised mean?

Type A-SI means the RCCB detects pulsating DC fault currents (Type A) and is Super Immunised against nuisance tripping from high-frequency harmonics and surge currents up to 3 kA. The SI suffix is tested per IEC 61008-1 for immunity to surge-induced tripping, making it stable on supplies with VFDs, UPS, or welding equipment.

What is the difference between this and a standard 30 mA RCCB?

The A9N16246 has 300 mA sensitivity for fire protection rather than 30 mA for personal shock protection, and it includes a selective time delay (40-150 ms) to coordinate with downstream 30 mA devices. A standard 30 mA RCCB trips faster and at a lower leakage threshold, so it goes on socket-outlet circuits while this unit protects the upstream feeder.

Where can I buy the A9N16246 and get current pricing?

The part is sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time — submit an RFQ for a firm commercial offer.