Schneider Electric A9N16253 Acti9 xID RCCB, 25A, 100mA, 4P

MPN A9N16253
Active

Schneider Electric Acti9 xID RCCB, A9N16253, 4P, 25 A rated current, 100 mA earth-leakage sensitivity, Type AC, 400...415 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N16253 specifications
ParameterValue
Control typeToggle
Voltage400...415 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
IP ratingIP20
Terminal pitch18 mm between phases
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-5 °C
Storage temperature-40...60 °C
Pollution degree2
ColorWhite
Depth75 mm
Width72 mm
Height81 mm
Electrical life cycles4000 cycles
Mechanical life cycles4000 cycles
Operating temperature-5...40 °C

Product details

The Schneider Electric A9N16253 is an Acti9 xID residual current circuit breaker (RCCB) — a 4-pole device rated for 25 A continuous current with 100 mA earth-leakage sensitivity, Type AC, for 400...415 V AC 50 Hz networks.

The 25 A [In] is the thermal continuous rating — the RCCB will carry that load indefinitely without tripping. The 100 mA sensitivity means it will disconnect when leakage to earth exceeds that threshold, which is typical for submain or feeder protection where a 30 mA device would nuisance-trip on cable capacitance. Type AC detection covers sinusoidal AC residual currents only; if the installation has rectified or pulsed DC fault currents (common with VFDs, LED drivers, or UPS-fed circuits), a Type A or Type B RCCB is needed instead. The instantaneous trip (no intentional delay) means it clears fast, but selectivity with upstream devices requires a time-delayed S-type RCCB or an MCB/RCCB combination. Insulation voltage is 500 V AC, and operational voltage is 400...415 V AC — this is a 4-pole unit for three-phase + neutral systems, neutral on the left. The 18 mm phase pitch and tunnel terminals accept up to 35 mm² rigid or 25 mm² flexible, with a 3.5 N·m tightening torque. Strip 15 mm for a reliable connection.

Deployment context

The toggle provides ON, OFF, and fault-trip local signalling, and a padlocking device can lock it in the OFF position for isolation (it is suitability-for-isolation certified).