Skip to main content
Schneider Electric A9N16258 — Residual Current Breakers (RCCB/RCBO)

A9N16258 Acti9 xID RCCB, 63 A, 30 mA, 4P, Type AC

MPNA9N16258
Active

Schneider Electric Acti9 xID, A9N16258, 4P residual current circuit breaker, 63 A, 30 mA, Type AC, 400-415 V AC, clip-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N16258 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Local signalling / indicationON, OFF, fault trip
A9N16258 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)400...415 V AC 50 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durability4000 cycles
Mechanical durability (operating cycles)4000 cycles
A9N16258 — Identification
ParameterValue
Product nameActi9 xID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short namexID
A9N16258 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsTunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height81 mm
Depth75 mm
A9N16258 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9N16258 — Approvals
ParameterValue
StandardsIEC 61008-2-1 EN 61008-2-1 EN/IEC 61008-1

Product details

The 63 A rated current means it handles the full incoming supply for a typical sub-main or large final circuit, not just a branch load.

Clip-on DIN rail mount, 72 mm wide — that's 8 modules of 9 mm pitch. Neutral on the left, 18 mm phase-to-phase terminal spacing. Tunnel terminals accept up to 35 mm² rigid or 25 mm² flexible; strip 14 mm and torque to 3.5 N.m. IP20 front, so it lives inside an enclosed panel, not on the wet side of the gland plate. The padlocking device and contact-position indicator make lockout/tagout straightforward for the field-service tech who has to swap it fast.

The Acti9 xID family is a standard line, so this order code is a straightforward BOM line item.

Frequently asked questions

What are the key ratings for the A9N16258?

63 A rated current, 30 mA earth-leakage sensitivity, Type AC, 4 poles, rated operational voltage 400-415 V AC at 50 Hz, breaking capacity 630 A per IEC 61008-1.

What compliance documentation covers this RCCB?

The A9N16258 is certified to IEC 61008-1, EN 61008-1, and EN/IEC 61008-2-1. It carries IP20 protection and meets tropicalisation class 2 per IEC 60068-1.

Where can I buy the A9N16258?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN
A9N16258