A9N16262 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Local signalling / indicationON, OFF, fault trip
A9N16262 — Electrical Ratings
ParameterValue
Rated current (In)80 A
Rated operational voltage (Ue)400...415 V AC 50 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durability4000 cycles
Mechanical durability (operating cycles)4000 cycles
A9N16262 — Identification
ParameterValue
Product nameActi9 xID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short namexID
A9N16262 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsTunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height81 mm
Depth75 mm
A9N16262 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9N16262 — Approvals
ParameterValue
StandardsEN 61008-2-1 IEC 61008-2-1 EN/IEC 61008-1

Product details

The Schneider Electric A9N16262 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 xID range, rated at 80 A with 100 mA earth-leakage sensitivity. It operates on a 400–415 V AC 50 Hz network and provides Type AC protection — meaning it detects sinusoidal AC residual currents only, suited for circuits without non-sinusoidal or pulsating DC fault profiles.

Integration Notes

Neutral is on the left. Local signalling shows ON, OFF, and fault trip status. A padlocking device can lock the toggle in the OFF position for isolation during maintenance — the device is marked as suitable for isolation (EN/IEC 61008-1). IP20 finger protection means it is intended for enclosure mounting — not for wet or dust-exposed locations. The ambient storage range is -40 to 85 °C, and the unit is tropicalised to class 2 per IEC 60068-1 (95 % RH at 55 °C).

Frequently asked questions

Where can I buy A9N16262?

The A9N16262 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of A9N16262?

Rated current 80 A, earth-leakage sensitivity 100 mA, Type AC, 4-pole, rated operational voltage 400–415 V AC 50 Hz, breaking capacity 800 A per EN/IEC 61008-1.

What compliance documentation does Schneider provide for A9N16262?

The device is certified to EN 61008-2-1 and IEC 61008-2-1, and conforms to EN/IEC 61008-1. It is tropicalised per IEC 60068-1 class 2.

What is A9N16262's listed depth?

The depth is 75 mm.

MPN