Skip to main content
Schneider Electric A9N16263 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N16263 Acti9 xID RCCB, 80 A, 300 mA, 4P

MPNA9N16263
Active

Schneider Electric Acti9 xID RCCB, 4P, 80 A, 300 mA Type AC, 400-415 V AC, clip-on DIN rail mount, IEC 61008-1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N16263 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Local signalling / indicationON, OFF, fault trip
A9N16263 — Electrical Ratings
ParameterValue
Rated current (In)80 A
Rated operational voltage (Ue)400...415 V AC 50 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durability4000 cycles
Mechanical durability (operating cycles)4000 cycles
A9N16263 — Identification
ParameterValue
Product nameActi9 xID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short namexID
A9N16263 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsTunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height81 mm
Depth75 mm
A9N16263 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9N16263 — Approvals
ParameterValue
StandardsIEC 61008-2-1 EN 61008-2-1 EN/IEC 61008-1

Product details

The Schneider Electric A9N16263 is an Acti9 xID residual current circuit breaker (RCCB) — a 4-pole, Type AC device rated for 80 A continuous current with 300 mA earth-leakage sensitivity. It operates on 400-415 V AC, 50 Hz networks and clips onto a DIN rail for panel mounting. The 300 mA sensitivity is the standard threshold for general-purpose socket-outlet and lighting circuits in commercial and industrial distribution boards, providing personnel protection against indirect contact while avoiding nuisance tripping on small leakage currents typical of permanently connected equipment.

Mounts via clip-on to DIN rail — 72 mm wide, 81 mm tall, 75 mm deep. The 4-pole unit occupies 8 module pitches (9 mm each) on the rail. Neutral is on the left. Tunnel-type terminals accept 1-35 mm² rigid or 1-25 mm² flexible cable; tighten to 3.5 N·m top or bottom.

Rated breaking and making capacity is 800 A conforming to EN/IEC 61008-1 — sufficient for clearing downstream faults in a residential or light commercial distribution board. Electrical and mechanical durability are both rated at 4000 cycles. The device is suitable for isolation (visible contact gap), with a contact position indicator and padlocking provision. Pollution degree 2 for normal industrial environments.

Frequently asked questions

What are the key ratings for A9N16263?

80 A rated current, 300 mA earth-leakage sensitivity, Type AC, 4-pole, rated operational voltage 400-415 V AC at 50 Hz, breaking capacity 800 A per IEC 61008-1.

Where can I buy A9N16263 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quotation.

What standards does A9N16263 comply with?

Compliant with IEC 61008-2-1, EN 61008-2-1, and EN/IEC 61008-1. Tropicalisation per IEC 60068-1 class 2.

MPN
A9N16263