Schneider Electric A9N16321 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N16321 Acti9 xID RCCB, 25A 30mA 4P

MPNA9N16321
Active

Schneider Electric Acti9 xID RCCB, 4P, 25A rated current, 30mA earth leakage sensitivity, 400-415V AC, Type A-SI super immunised, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N16321 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delayInstantaneous
Local signalling / indicationON, OFF, fault trip
A9N16321 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)400...415 V AC 50 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)6 kV
Electrical durability4000 cycles
Mechanical durability (operating cycles)4000 cycles
A9N16321 — Identification
ParameterValue
Product nameActi9 xID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short namexID
A9N16321 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsTunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height81 mm
Depth75 mm
A9N16321 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
Pollution degree2
Relative humidity95 % at 55 °C
Tropicalisation2 conforming to IEC 60068-1
A9N16321 — Approvals
ParameterValue
StandardsEN/IEC 61008-1 EN 61008-2-1 IEC 61008-2-1

Product details

The Schneider Electric A9N16321 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 xID series, rated at 25 A with 30 mA earth-leakage sensitivity. The Type A-SI (Super Immunised) designation means it handles pulsed DC fault currents from single-phase rectifiers and resists nuisance tripping from high-frequency leakage typical of VFDs and UPS systems — a common requirement on mixed-load panels.

Rated breaking and making capacity is 500 A per EN/IEC 61008-1. That figure governs the RCCB's ability to clear a fault without welding contacts — adequate for downstream protection in a sub-distribution board but not a main incomer; selectivity with an upstream MCB or MCCB needs coordination study. Rated insulation voltage (Ui) is 500 V AC, and rated operational voltage (Ue) is 400–415 V AC — the standard 3-phase + neutral supply in European LV networks. The 4P construction switches all four poles (, L2, L3, N) simultaneously, with neutral on the left side per the connection pitch of 18 mm between phases. The 25 A rating matches a typical feeder for lighting, socket outlets, or small mixed loads. Electrical and mechanical durability are both 4000 cycles — this is a protection device, not a switching contactor; it is designed to sit closed for years and trip only on fault, not for frequent manual operation.

Tunnel terminals accept 1–35 mm² rigid or 1–25 mm² flexible cable; wire stripping length is 14 mm, and tightening torque is 3.5 N·m top or bottom. IP20 rated — suitable for dry indoor enclosures only. The toggle control provides ON, OFF, and fault-trip local signalling, with a contact position indicator and provision for a padlocking device to lock the circuit off for maintenance isolation.

Standards compliance includes EN/IEC 61008-1 and IEC 61008-2-1, with tropicalisation class 2 per IEC 60068-1 (resistance to heat and humidity up to 95% RH at 55 °C).

Frequently asked questions

What is the closest alternative to A9N16321 in the same family?

Within the Acti9 xID range, the closest sibling differs by rated current or pole count — for example, a 40 A 4P variant or a 25 A 2P variant. There is no pin-compatible drop-in; the selection depends on the feeder current and the number of poles required.

Where can I buy A9N16321 and what is the lead time?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead-time commitment.

What compliance documentation does Schneider provide for A9N16321?

The RCCB is certified to EN/IEC 61008-1 and IEC 61008-2-1, with tropicalisation per IEC 60068-1. Standard Schneider documentation includes the declaration of conformity (CE/UKCA) and the product datasheet. RoHS and REACH compliance are standard for the Acti9 range.

MPN
A9N16321