Schneider Electric A9N18360 Acti9 C120N MCB, 63 A, C Curve,

MPN A9N18360
Active

Schneider Electric Acti9 C120N, A9N18360, miniature circuit breaker, 2P, 63 A, C curve, 10 kA Icn at 400 V AC, thermal-magnetic trip, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18360 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

A9N18360 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width54 mm
Height81 mm
Electrical life cycles10000 cycles conforming to IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9N18360 is an Acti9 C120N miniature circuit breaker rated 63 A at 30 °C with a C curve (magnetic trip between 5 and 10 times In). The dual rating to EN/IEC 60947-2 (6 kA Icu at 440 V, 10 kA Icu at 380–415 V) also qualifies it for industrial control panel use where the standard demands 60947-2 rather than 60898-1. The thermal-magnetic trip unit provides overload protection via a bimetal strip and short-circuit protection via a solenoid, a mature technology that requires no auxiliary power for trip operation.

Deployment context

Rated for distribution in AC networks at 50/60 Hz, this 2-pole breaker protects two poles — typically a single-phase line and neutral, or two legs of a three-phase system where a 2-pole device is needed for a 240 V split-phase supply. The IP20 finger-safe terminals are suitable for enclosed panels; the breaker is not rated for washdown environments.

Tunnel-type terminals accept 1–50 mm² rigid or 1.5–35 mm² flexible conductors. The neutral position is on the left — maintain that orientation when bus-barring multiple breakers in a panel to keep phase alignment consistent.