Skip to main content
Schneider Electric A9N18377

Schneider Electric A9N18377 Acti9 C120 MCB, 125 A, C Curve,

MPN A9N18377
Active

Schneider Electric Acti9 C120, miniature circuit breaker, 4P, 125 A, C curve, 10 kA Icn at 400 V AC, clip-on DIN rail.

$128.01 – $212.12 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18377 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 500 V DC conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

A9N18377 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width108 mm
Height81 mm
Electrical life cycles5000 cycles conforming to IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9N18377 is a 4-pole Acti9 C120 miniature circuit breaker rated 125 A at 30 °C, with a C-curve magnetic trip (5–10 × In) and a thermal-magnetic trip unit. It clips onto a 35 mm symmetrical DIN rail for panel mounting. Breaking capacity: 10 kA Icn at 400 V AC per EN/IEC 60898-1, and 10 kA Icu at 380–415 V AC per EN/IEC 60947-2.

Integration notes

Width is 108 mm (12 × 9 mm pitches). Tunnel terminals accept 1–50 mm² rigid or 1.5–35 mm² flexible wire; strip length 15 mm, torque to 3.5 N·m. Neutral on the left, 4 protected poles, toggle control with ON/OFF local indication. Earth-leakage protection requires a separate block — not integrated. Suitable for isolation per IEC 60947-2.

MPN