Skip to main content
Schneider Electric A9N18383 — 2-Pole MCB (DIN Rail)

Schneider Electric A9N18383 Acti9 C120N MCB, 80 A D Curve, 2

MPNA9N18383
Active

Schneider Electric Acti9 C120N miniature circuit breaker, A9N18383, 80 A rated current, D curve, 2-pole, 10 kA breaking capacity at 400 V AC, clip-on 35 mm DIN rail mount.

$482.76Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

A9N18383 — Identification
ParameterValue
Product nameActi9 C120
Series / familyActi9
Device short nameC120N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N18383 — Electrical
ParameterValue
Rated current [In]80 A at 30 °C
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N18383 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu)10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]7500 A 75 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Energy limitation class3 conforming to EN/IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N18383 — Mechanical
ParameterValue
9 mm pitches6
Width54 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals1...50 mm² rigid Tunnel type terminals1.5...35 mm² flexible
Terminal tightening torque3.5 N.m
Comb busbar / distribution block compatibilityYES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N18383 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N18383 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9N18383 is an Acti9 C120N miniature circuit breaker rated 80 A at 30 °C with a D tripping curve (magnetic trip 10–14 x In). It's a 2-pole (2P) device for AC networks, breaking 10 kA Icn at 400 V AC per EN/IEC 60898-1 and 6 kA Icu at 440 V AC per EN/IEC 60947-2.

The tunnel terminals accept 1–50 mm² rigid or 1.5–35 mm² flexible, stripped 15 mm, torqued to 3.5 N·m. IP20 finger-safe front, pollution degree 3, overvoltage category IV — standard for main distribution panels. Neutral on the left, toggle control with ON/OFF indication.

The Acti9 C120 range is Schneider's heavy-duty residential and light-commercial MCB platform, and this 80 A D-curve variant is a standard catalogue item.

Frequently asked questions

What is the closest pin-compatible alternative to A9N18383 in this component family?

Within the Acti9 C120N family, the closest sibling is a different current rating or pole count — same footprint, same DIN-rail clip, same terminal layout. The D-curve and 2-pole configuration are what define the fit for high-inrush two-phase loads.

What compliance documentation does this brand provide for A9N18383?

The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1, with IP20 protection per IEC 60529 and tropicalisation class 2 per IEC 60068-1. Standard Schneider documentation includes the declaration of performance and CE declaration of conformity.

MPN