Skip to main content
Schneider Electric A9N18412 — 2-Pole MCB (DIN Rail)

Schneider Electric A9N18412 Acti9 C120H MCB, B Curve 63 A 2P

MPNA9N18412
Active

Schneider Electric Acti9 C120H, A9N18412, miniature circuit breaker, B curve, 63 A, 2P, 15 kA Icn at 400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N18412 — Identification
ParameterValue
Product nameActi9 C120
Series / familyActi9
Device short nameC120H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N18412 — Electrical
ParameterValue
Rated current [In]63 A at 30 °C
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N18412 — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu)15000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]7500 A 50 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Energy limitation class3 conforming to EN/IEC 60947-2
Suitable for isolationYes conforming to IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N18412 — Mechanical
ParameterValue
9 mm pitches6
Width54 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals1...50 mm² rigid Tunnel type terminals1.5...35 mm² flexible
Terminal tightening torque3.5 N.m
Comb busbar / distribution block compatibilityYES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N18412 — Environmental
ParameterValue
Operating temperature range-30...60 °C
Storage temperature range-40...70 °C
Relative humidity95 % at 55 °C
A9N18412 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9N18412 is an Acti9 C120H miniature circuit breaker (MCB) with a B tripping curve, rated 63 A at 30 °C, 2 poles, and a 15 kA Icn breaking capacity at 400 V AC.

Rated to dual standards EN/IEC 60898-1 and EN/IEC 60947-2, so it qualifies for both residential and industrial distribution panels. The 15 kA Icn at 400 V AC (per 60898-1) handles high-fault utility feeds; the 10 kA Icu at 440 V AC (per 60947-2) covers industrial motor-start transients.

Trip curve and application

B curve means magnetic trip between 3 and 5 times In (189–315 A for this 63 A unit). That suits resistive and general-purpose loads — lighting, small transformers, control circuits — where inrush is modest. Thermal-magnetic trip technology handles overloads (thermal bimetal) and short-circuits (solenoid) in one package.

IP20 finger-safe terminals accept 1–50 mm² rigid or 1.5–35 mm² flexible wire; tunnel-type terminals with a 3.5 N·m tightening torque and 15 mm strip length. Pollution degree 3 (conductive pollution) and overvoltage category IV suit main distribution boards.

Frequently asked questions

Where can I buy A9N18412 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

What is A9N18412's breaking capacity at 400 V?

It has a 15 kA Icn at 400 V AC per EN/IEC 60898-1, and a 15 kA Icu at 380–415 V AC per EN/IEC 60947-2.

What is the B curve magnetic trip range for A9N18412?

The magnetic trip operates between 3 and 5 times the rated current (In), so 189 to 315 A for this 63 A unit.

What compliance documentation does Schneider provide for A9N18412?

The part is certified to EN/IEC 60898-1 and EN/IEC 60947-2. It carries IP20 protection per IEC 60529 and tropicalisation class 2 per IEC 60068-1.

MPN
A9N18412