Skip to main content
Schneider Electric A9N18412

Schneider Electric A9N18412 Acti9 C120H MCB, B Curve 63 A 2P

MPN A9N18412
Active

Schneider Electric Acti9 C120H, A9N18412, miniature circuit breaker, B curve, 63 A, 2P, 15 kA Icn at 400 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18412 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-30 °C
Storage temperature-40...70 °C
Pollution degree3 conforming to IEC 60947-2

All specifications

A9N18412 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width54 mm
Height81 mm
Electrical life cycles10000 cycles conforming to IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...60 °C

Product details

The Schneider Electric A9N18412 is an Acti9 C120H miniature circuit breaker (MCB) with a B tripping curve, rated 63 A at 30 °C, 2 poles, and a 15 kA Icn breaking capacity at 400 V AC.

Rated to dual standards EN/IEC 60898-1 and EN/IEC 60947-2, so it qualifies for both residential and industrial distribution panels. The 15 kA Icn at 400 V AC (per 60898-1) handles high-fault utility feeds; the 10 kA Icu at 440 V AC (per 60947-2) covers industrial motor-start transients.

Trip curve and application

B curve means magnetic trip between 3 and 5 times In (189–315 A for this 63 A unit). That suits resistive and general-purpose loads — lighting, small transformers, control circuits — where inrush is modest. Thermal-magnetic trip technology handles overloads (thermal bimetal) and short-circuits (solenoid) in one package.

IP20 finger-safe terminals accept 1–50 mm² rigid or 1.5–35 mm² flexible wire; tunnel-type terminals with a 3.5 N·m tightening torque and 15 mm strip length. Pollution degree 3 (conductive pollution) and overvoltage category IV suit main distribution boards.

MPN