Skip to main content
Schneider Electric A9N18500

Schneider Electric A9N18500 Acti9 C120H MCB, 63 A D Curve, 2

MPN A9N18500
Active

Schneider Electric Acti9 C120H, A9N18500, miniature circuit breaker, 2P, 63 A, D curve, 15 kA Icn at 400 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18500 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity15000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-30 °C
Storage temperature-40...70 °C

All specifications

A9N18500 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width54 mm
Height81 mm
Electrical life cycles10000 cycles conforming to IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...60 °C

Product details

The A9N18500 is a 2-pole miniature circuit breaker from the Acti9 C120H range, rated 63 A at 30 °C with a D tripping curve (magnetic trip 10–14 × In). The D curve means it tolerates the high inrush of motor and transformer loads without nuisance tripping — the magnetic trip won't fire until the fault hits 10 to 14 times the 63 A rating, so a 3-phase motor starting at 6× FLC coasts right through. Breaking capacity is 15 kA Icn at 400 V AC per EN/IEC 60898-1, and 10 kA Icu at 440 V AC per EN/IEC 60947-2 — that's enough for most industrial distribution panels downstream of a 200 kVA transformer.

Dual-standard compliance and isolation

This breaker carries both EN/IEC 60898-1 (MCB standard) and EN/IEC 60947-2 (industrial circuit-breaker standard) approvals. That dual rating means it's accepted for residential and commercial boards (60898-1) and for industrial panels where the higher Icu and isolation requirements of 60947-2 apply.

MPN
A9N18500