Skip to main content
Schneider Electric A9N18545 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N18545 Vigi C120 RCD, 2P 125A 1000mA AC

MPNA9N18545
Active

Schneider Electric Acti9 Vigi C120, A9N18545, add-on residual current device, 2P, 125A, AC type, selective, 1000mA, 230...415V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N18545 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)1000 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delaySelective
Residual-current tripping technologyVoltage independent
A9N18545 — Electrical Ratings
ParameterValue
Rated current (In)125 A
Rated operational voltage (Ue)230...415 V AC 50/60 Hz
Poles description2P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-1
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer Group incomer
Mechanical durability (operating cycles)20000 cycles
A9N18545 — Identification
ParameterValue
Product nameActi9 Vigi C120
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi C120
A9N18545 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeClip-on
Width in 9 mm modules7
Terminal connectionsTunnel type terminals 1...35 mm² flexible Tunnel type terminals 1...50 mm² rigid
Wire stripping length15 mm
Terminal tightening torque3.5 N.m
Width117 mm
Height95 mm
Depth73 mm
A9N18545 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...60 °C
IP degree of protectionIP20
Pollution degree3 conforming to IEC 60947-2
A9N18545 — Approvals
ParameterValue
StandardsEN 61009 IEC/EN 61009-2-1

Product details

Rated 125 A at 230...415 V AC, it provides 1000 mA AC-type residual current protection with a selective (time-delayed) trip characteristic, meaning it coordinates downstream so only the faulted branch clears first.

The 125 A rated current (In) matches high-current outgoing feeders or incomer positions in distribution boards. The 1000 mA sensitivity is a selective (delayed) trip — it's not for personnel protection (which requires 30 mA) but for equipment-level earth-fault protection with coordination downstream. AC-type detection handles sinusoidal residual currents only; if your loads include rectifiers, VFDs, or switched-mode supplies, you'd need Type A or Type B instead. The 230...415 V AC operational voltage covers single-phase and three-phase networks up to 415 V phase-to-phase.

Electrical connection to the MCB is by screws (tunnel terminals accepting 1...35 mm² flexible or 1...50 mm² rigid). The 2-pole (2P) format fits single-phase or two-wire circuits.

Frequently asked questions

How do I get current pricing and availability for A9N18545?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

What are the key ratings for A9N18545?

125 A rated current, 1000 mA AC-type earth-leakage sensitivity, selective time delay, rated operational voltage 230...415 V AC, pollution degree 3, IP20 enclosure.

What compliance standards does A9N18545 meet?

It complies with EN 61009, IEC/EN 61009-2-1, and IEC 60947-2 (pollution degree 3, rated impulse withstand voltage 6 kV).

MPN
A9N18545