Skip to main content
Schneider Electric A9N18568 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N18568 Vigi C120 3P 125A 500mA RCD, Act

MPNA9N18568
Active

Schneider Electric Acti9 Vigi C120 add-on residual current device, A9N18568, 3P, 125 A, 500 mA, Type AC, instantaneous, 230…415 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

A9N18568 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)500 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9N18568 — Electrical Ratings
ParameterValue
Rated current (In)125 A
Rated operational voltage (Ue)230...415 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-1
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer Group incomer
Mechanical durability (operating cycles)20000 cycles
A9N18568 — Identification
ParameterValue
Product nameActi9 Vigi C120
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi C120
A9N18568 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeClip-on
Width in 9 mm modules10
Terminal connectionsTunnel type terminals 1...35 mm² flexible Tunnel type terminals 1...50 mm² rigid
Wire stripping length15 mm
Terminal tightening torque3.5 N.m
Width171 mm
Height95 mm
Depth73 mm
A9N18568 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...60 °C
IP degree of protectionIP20
Pollution degree3 conforming to IEC 60947-2
A9N18568 — Approvals
ParameterValue
StandardsEN 61009 IEC/EN 61009-2-1

Product details

The Schneider Electric A9N18568 is an add-on residual current device (RCD) from the Acti9 Vigi C120 range, designed to clip onto a compatible Acti9 MCB or MCCB via screw connection, providing earth-leakage protection downstream. It is a 3-pole unit rated for 125 A continuous current, with a 500 mA sensitivity and Type AC detection — meaning it trips on sinusoidal AC residual currents only, instantaneous response. The voltage-independent tripping mechanism means it operates without needing an external supply, even if the line voltage drops. Rated operational voltage is 230…415 V AC at 50/60 Hz, with an insulation voltage of 500 V AC and impulse withstand of 6 kV per IEC 60947-2. Mounts via clip-on to a 35 mm symmetrical DIN rail, occupying 10 x 9 mm pitches (171 mm width). Terminals accept 1…50 mm² rigid or 1…35 mm² flexible cable; tightening torque is 3.5 N·m.

Frequently asked questions

Where can I buy the A9N18568 and get a price?

The A9N18568 is sourced to order against an RFQ through independent distribution channels. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is the A9N18568's earth-leakage sensitivity and type?

It is a Type AC RCD with 500 mA sensitivity and instantaneous tripping, meaning it detects sinusoidal AC residual currents only and trips without intentional delay.

What standards does the A9N18568 comply with?

It complies with EN 61009 and IEC/EN 61009-2-1, with pollution degree 3 per IEC 60947-2 and 6 kV impulse withstand voltage per IEC 60947-2.

MPN