Schneider Electric A9N18574

Schneider Electric A9N18574 Vigi C120 RCD Add-On Block, 125

MPN A9N18574
Active

Schneider Electric Vigi C120 add-on residual current device, 2P, 125 A, 500 mA sensitivity, Type A, 73 mm depth, white, obsolete.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18574 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230...415 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-1
IP ratingIP20
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width117 mm
Height95 mm
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

It's voltage-independent, meaning the trip mechanism doesn't rely on the line voltage to operate — a useful reliability feature if the neutral is lost upstream. The tunnel terminals accept up to 50 mm² rigid or 35 mm² flexible cable. Rated operational voltage covers 230–415 V AC 50/60 Hz, with an insulation voltage of 500 V and impulse withstand of 6 kV per IEC 60947-2. The 73 mm depth and 117 mm width mean it takes up a standard modular space on the rail — 9 mm pitches × 7, so it occupies 7 modules of DIN width. IP20 rated, so it's for inside a panel only, not washdown areas.

Designed and tested to EN 61009 and IEC/EN 61009-2-1, plus IEC 60947-2 for the impulse withstand and pollution degree 3 rating. The Type A classification covers the most common fault types in mixed-load panels.

The 125 A rated current is the continuous load it can carry — sized for a main incomer or a large subfeed in a distribution board. The 500 mA sensitivity is a deliberate choice: it's less sensitive than a 30 mA RCD, so it won't nuisance-trip on normal leakage from long cable runs or equipment filters. Use it where the goal is fire protection or equipment protection, not personal shock protection (that needs 30 mA or lower). Instantaneous trip time means no intentional delay — it reacts as soon as the fault current exceeds 500 mA. That's fine for a main switch, but if you need selectivity downstream, you'd want a time-delayed (S-type) RCD instead.